期刊文献+

Pretreatment of heterocyclic pesticide wastewater using ultrasonic/ozone combined process 被引量:9

Pretreatment of heterocyclic pesticide wastewater using ultrasonic/ozone combined process
原文传递
导出
摘要 Ultrasonic/O3 combined process was employed to pretreat heterocyclic pesticide wastewater for increasing biodegradability and reducing biological toxicity. Influences of ultrasonic frequency, ultrasonic power, probe diameter, initial pH and 03 dosage on the COD removal were studied. The results showed that the ultrasonic/O3 process significantly improved the biodegradability and reduced the biological toxicity of the wastewater. The ratio of BODs/COD was increased from 0.03 to 0.55 and the EC50 increased from 11% to 52% under ultrasonic/O3 treatment. Low ultrasonic frequency brought better COD removal. Initial pH was found to have a high influence on the COD removal and alkaline conditions were more favorable. The influences of ultrasonic power and probe diameter were small. With an increase in O3 dosage, COD removal was effectively improved. The optimal operational parameters for the combined process on COD removal were ultrasonic frequency 20 kHz, initial pH 9.00, ultrasonic power 300 W and dosage of O3 454.8 mg/(L.min), under which the efficiency of COD removal reached 67.2%. Ultrasonic/O3 combined process was employed to pretreat heterocyclic pesticide wastewater for increasing biodegradability and reducing biological toxicity. Influences of ultrasonic frequency, ultrasonic power, probe diameter, initial pH and 03 dosage on the COD removal were studied. The results showed that the ultrasonic/O3 process significantly improved the biodegradability and reduced the biological toxicity of the wastewater. The ratio of BODs/COD was increased from 0.03 to 0.55 and the EC50 increased from 11% to 52% under ultrasonic/O3 treatment. Low ultrasonic frequency brought better COD removal. Initial pH was found to have a high influence on the COD removal and alkaline conditions were more favorable. The influences of ultrasonic power and probe diameter were small. With an increase in O3 dosage, COD removal was effectively improved. The optimal operational parameters for the combined process on COD removal were ultrasonic frequency 20 kHz, initial pH 9.00, ultrasonic power 300 W and dosage of O3 454.8 mg/(L.min), under which the efficiency of COD removal reached 67.2%.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2011年第5期725-730,共6页 环境科学学报(英文版)
基金 supported by the National Water Pollution Control and Management Technology Major Project(No. 2008ZX07316-003)
关键词 heterocyclic pesticide wastewater ULTRASONIC O3 BOD5/COD biological toxicity heterocyclic pesticide wastewater ultrasonic O3 BOD5/COD biological toxicity
  • 相关文献

参考文献6

二级参考文献59

共引文献125

同被引文献112

引证文献9

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部