期刊文献+

320层DVCT扇区重建技术对心率波动患者冠脉图像质量的影响 被引量:5

Influence of segment reconstruction technique on the image quality of coronary artery with 320-slice dynamic volume CT in patients with heart rate fluctuation
下载PDF
导出
摘要 目的:探讨扇区重建技术对心率波动患者冠脉图像质量的影响,寻找合适的重建方法以提高心率波动患者的冠脉图像质量。方法:39例心率波动患者行320层动态容积CT冠状动脉成像,分别采用半重建法(half)和多扇区重建法选择最佳时相对冠脉图像进行重建,分析两种重建方法下图像质量与扫描时的最低心率以及心率波动范围之间的相关性。结果:采用half重建法,有94.87%的图像可满足诊断,采用多扇区重建法,有87.18%的图像可满足诊断。两种重建方法下图像质量与心率波动范围之间均无相关性;采用half重建时,图像质量与描时的最低心率呈负相关(r=-0.351,P=0.028)。结论:运用320层容积CT进行冠状动脉成像,选择最低心率所对应的单一心动周期进行half重建,可明显提高心率波动患者的冠脉图像质量。 Objective:To evaluate the effect of segment reconstruction technique on the image quality of coronary artery in patients with heart rate fluctuation,and to seek the appropriate reconstruction technique,in order to improve the image quality.Methods:Thirty-nine patients with heart rate fluctuation were studied with 320-slice dynamic volume CT(DVCT),half as well as segment reconstruction technique were used to recombine coronary images on optimal reconstruction phase.Pearson correlation was used to analyze the relationship between image quality and the minimal heart rate as well as heart rate fluctuation during CT scanning with the two reconstruction techniques.Results:Using half reconstruction technique,94.87% of the images fulfilled the quality requirement of diagnosis and 87.18% of images fulfilled the requirement as segment reconstruction was adopted.No correlation between image quality and heart rate fluctuation was showed with these two reconstruction techniques.The minimal heart rate had negative correlation with image quality when using half reconstruction technique(r=-0.351,P=0.028).Conclusion:To perform CT-CAA with 320-slice DVCT,half reconstruction technique corresponded with the minimal heart rate in a single cardiac cycle can obviously improve the image quality of coronary artery in patients with heart rate fluctuation.
出处 《放射学实践》 北大核心 2011年第4期449-452,共4页 Radiologic Practice
关键词 体层摄影术 X线计算机 放射摄影术 图像处理 计算机辅助 冠脉成像 Tomography X-ray computed Radiography Image processing computer-assisted Coronary image
  • 相关文献

参考文献7

二级参考文献29

  • 1姜荣,吴晓华,贺文.心率波动对多层螺旋CT冠脉造影图像质量的影响[J].中国医学影像技术,2004,20(10):1574-1576. 被引量:49
  • 2杨明放,王荣品,何强.16层CT冠状动脉成像技术及临床应用[J].实用放射学杂志,2005,21(9):915-918. 被引量:21
  • 3张敏,李石玲,郭智萍,张英华,王凤珍.64层螺旋CT冠状动脉血管成像技术[J].中国医学影像技术,2005,21(12):1948-1950. 被引量:24
  • 4龚艳君,霍勇.64排CT冠状动脉成像的临床应用现况[J].中国介入心脏病学杂志,2005,13(6):416-416. 被引量:26
  • 5张竹花 金征宇 李冬晶 等.多层螺旋CT冠状动脉成像研究[J].中华放射学杂志,2003,37(9):147-147.
  • 6Nieman K,Cademartiri F,Lemos PA,et al.Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.Circulation,2002,106:2036-2038.
  • 7Ropers D,Baum U,Pohle K,et al.Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.Circulation,2003,107:664-666.
  • 8Flohr TG,Schoepf UJ,Kuettner A,et al.Advances in cardiac imaging with 16-section CT systems.Acad Radiol,2003,10:386-401.
  • 9Detre KM,Wright E,Murphy ML,et al.Observer agreement in evaluating coronary angiograms.Circulation,1975,52:979-986.
  • 10Austen WG,Edwards JE,Frye RL,et al.A reporting system on patients evaluated for coronary artery disease.Report of the Ad-Hoc Committee for Grading of Coronary Artery Disease,Council on Cardiovascular Surgery.Circulation,1975,51:5-40.

共引文献204

同被引文献36

  • 1姜荣,吴晓华,贺文.心率波动对多层螺旋CT冠脉造影图像质量的影响[J].中国医学影像技术,2004,20(10):1574-1576. 被引量:49
  • 2祁吉,沈云,吴胜勇,葛夕洪,姜滨.新型心脏动态体模及其在多层螺旋CT心脏扫描中的应用[J].中华放射学杂志,2006,40(9):988-990. 被引量:18
  • 3Ruben C, Matthew R, Dorcas O, et al. High doses of Ketamine- Xylazine anesthesia reduce cardiac isehemia-reperfusion injury in guinea pigs[J]. J Am Assoe Lab Anita Sci, 2011,50 (3) : 349- 354.
  • 4Udo H,Ryan M, Christian E, et al. Acute myocardial infarction: contrast-enhanced multi-detector row CT in a porcine model[J]. Radiology, 2004,231 (3) :697-701.
  • 5Brodoefel H,Klumpp B, Reimann A, et al. Late myocardial enhancement assessed by 64-MSCT in reperfused porcine myocardial infarction: diagnostic accuracy of low-dose CT protocols in comparison with magnetic resonance imaging [ J ]. Eur Radiol, 2007, 17 ( 2 ) : 475 - 483.
  • 6Martini C,Maffei E,Palumbo A,et al. Impact of contrast material volume on quantitative assessment of reperfused acute myocardial infarction using delayed-enhancement 64-slice CT: experience in a porcine model[J]. Radiol Med,2010,115(7) :22-35.
  • 7Johnson D M, Geys R, Lissens J, et al. Drug-induced effects on cardiovascular function in pentobarbital anesthetized guinea-pigs: invasive LVP measurements versus the QA interval[J]. J Pharmacol Toxicol Method, 2012,66(2) : 152- 159.
  • 8Steigner M L,Otero H J,Cai T,et al. Narrowing the phase win dow width in prospectively ECG-gated single heart beat 320-de teetor row coronary CT angiography[J]. Int J Cardiovase Ima ging,2009,25(1) :85 90.
  • 9Shen J, Du X,Guo D, et al. Prospective ECG-triggered coronary CT angiography: clinical value of noise-based tube current reduction method with iterative reconstruction [J ]. PLoS one, 2013,8 ( 5 ) : e65025.
  • 10Sun Z, Ng K H. Prospective versus retrospective ECG-gated mulfislice CTcoronary angiography: a systematic review of radiation close and diagnostic accuracy[J]. Eur J Radiol, 2012,81 (2) : e94 - e100.

引证文献5

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部