摘要
参照光学金相分析及工艺条件对奥氏体材质的换热管失效机理进行了探讨,并提出了相应的预防措施.
The mechanisms of failure of austenitic heat exchanger tubes was studied based upon the optic metallographical analysis and process conditions. The respective preventive measures were presented.
出处
《石油化工腐蚀与防护》
CAS
1999年第2期25-26,34,共3页
Corrosion & Protection In Petrochemical Industry
关键词
奥氏体
换热管
锅炉
给水
制氢
austenite, heat exchanger tube, failure