摘要 消防系统关系到人身及财产安全,一直是设计及审查的重点。关于火灾状态下非消防电源的切除要求各规范中早有规定,但随着生活水平的提高,非消防电源的分类日趋复杂。就火灾状态下如何合理切断非消防电源进行了论述,希望电气设计师在设计过程中加深对众多规范的理解,使设计成果更加合理。 Fire fighting system is related to personal property and is importance in design and examination.The rules about cutting off non-fine power supply under firing had be early set.But following the improvement of people's life,the classification of non-fire power supply became core complicated.How to reasonably cut off non-fire power supply under firing was expounded.It is hoped to help the electrical designers to get deeply comprehension on many rules and made the design more reasonable.
作者 樊海东
出处 《现代建筑电气》 2011年第4期51-53,共3页 Modern Architecture Electric
关键词 民用建筑 非消防电源 电气火灾 负荷等级 切除区域 civil building non-fire fight power electric fire load level cut-off area