期刊文献+

基于NTN校准的等效采样示波器任意频率栅相位响应重构 被引量:1

Phase response reconstruction of arbitrary frequency grid for equivalent sampling oscilloscope based on NTN calibration
下载PDF
导出
摘要 研究提出了一种通过测量等效采样示波器幅度响应来获得其相位响应的算法。此方法是基于Kram ers-Kron ig关系式并配以基于NTN校准的相位响应测量实现的。实例证明:虽然Kram ers-Kron ig变换计算时的截断造成了相位估计上非常大的误差,但是此误差可以通过少量的正交基函数拟合出来。作为一个实例,本文利用NTN校准和扫频法校准的结果获得了等效采样示波器的复频率响应,在1 MHz^50 GHz频率范围内,其频率分辨率达到了1 MHz。重构出的相位响应标准不确定度小于0.6°。结果表明:此方法可以重构出等效采样示波器任意频率栅复频率响应。 Describes an algorithm for determining the minimum phase response of equivalent sampling oscilloscopes.The procedure is based on Kramers-Kronig relation in combination with the harmonic phase response measurement of NTN calibration.Although the truncation of Kramers-Kronig transform gives rise to large errors in estimated phase,these errors can be fitted using three basis functions.As an example,we got the phase response reconstruction of sampling oscilloscope in frequency domain;its frequency resolution achieves 1MHz in the frequency range from 1 MHz^50 GHz,and the phase uncertainty of the phase response is less than 0.6°.These results are based on the data obtained using an NTN technique in combination with swept-sine calibration procedure.The above results show that the algorithm can be used to obtain fine phase response of equivalent sampling oscilloscopes.
机构地区 哈尔滨工业大学
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2011年第5期989-995,共7页 Chinese Journal of Scientific Instrument
基金 国家自然科学基金(NSFCNo.60772078) 教育部博士点基金(RFDPNo.20070213026) 总装备部2010~2012年度通用测试技术预研基金资助项目
关键词 NTN校准 Kramers-Kronig变换 等效采样示波器 相位响应重构 NTN calibration Kramers-Kronig transform equivalent sampling oscilloscope phase response reconstruction
  • 相关文献

参考文献5

二级参考文献20

共引文献24

同被引文献15

  • 1READER H C, WILLIAMS D F, HALE P D , et al. Comb generator characterization [ J ]. IEEE Transc- tionson Microwave Theory and Techniques, 2008, 56(2) : 515-521.
  • 2RODWELL M J W, KAMEGAWA M, YU R, et al. GaAs nonlinear transmission lines for picosecond pulse generation and millimeter-wave sampling [ J ]. IEEE Trans. Microwave Theory and Techniques, 1991, 39(7) : 1194- 1204.
  • 3WILLIAMS D F, CLEMENT T S, REMLEY K A, et al. Systematic error of the nose-to-nose sampling oscilloscope calibration [ J]. IEEE Transactions Microwave Theory and Techniques, 2007, 55(9): 1951-1957.
  • 4WILLIAMS D F, HALE P D, CLEMENT T S, et al. Calibrating electro-optic sampling systems [ C ]. IEEE MTT-S Digest, 2001 : 1527-1530.
  • 5WANG C M, HALE P D, COAKLEY K J. Least squares estimation of timebase distortion of sampling oscilloscopes[ J]. IEEE Transactions on Instrumenta- tion and Measurement, 1999, 48(6) : 1324-1332.
  • 6HALE P D, WANG C M, WILLIAMS D F, et al. Com- pensation of random and systematic timing errors in sam- piing oscilloscopes[ J]. IEEE Transactions on Instrumen- tation and Measurement, 2006, 55 (6) : 2146-2154.
  • 7WILLIAMS D F, LEWANDOWSKI A, CLEMENT T S, et al. Covariance based uncertainty analysis of the NIST electro optic sampling system [ J]. IEEE Transactions on Microwave Theory and Techniques, 2006, 54 ( 1 ) : 481-491.
  • 8WANG C M, HALE P D, JARGON J A, et al. Sequen- tial estimation of timebase corrections for an arbitrarily long waveform[ J ]. IEEE Transactions on Instrumentation and Measurement, 2012, 64 (10) : 2689-2694.
  • 9ZHANG Y CH, LIN M L. A new NVNA phase reference for poly-harmonic intermodulation measurements [ J ]. IEEE Transactions on Instrumentation and Measurement, 2013, 62(6): 1467-1472.
  • 10夏莹,周勃.非线性传输线梳状谱发生器的设计[J].科学技术与工程,2010,10(36):9094-9098. 被引量:3

引证文献1

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部