摘要 目的:建立马来酸桂哌齐特注射液的细菌内毒素检查方法。方法:按照《中国药典》2010年版(二部)附录细菌内毒素检查法,用2个不同厂家的鲎试剂对3批马来酸桂哌齐特注射液进行干扰试验和细菌内毒素检查。结果:供试品溶液在浓度为0.5mg·mL-1时对鲎试剂与细菌内毒素之间的凝集反应有抑制现象,而浓度低于或等于0.25mg·mL-1时不干扰细菌内毒素检查;样品的细菌内毒素限值确定为1.0EU·mg-1。结论:建立的细菌内毒素检查方法可行,可用于马来酸桂哌齐特注射液的检查。 OBJECTIVE: To establish a method for the detection of bacterial endotoxins in Cinepazide maleate injection. METHODS : The interference experiment and bacterial endotoxins test of 3 batches of Cinepazide maleate injection were carried out with tachypleus amebocyte lysate from 2 companies according to the guideline and procedures specified in appendix of volume two in Chinese Pharmacopoeia (2010 edition). RESULTS: It was proved that the samples with concentration of over 0.5 mg. mL-1 in- hibited the congregating reactivity between tachypleus amebocyte lysate and bacterial endotoxins. However, this interference was eliminated by diluting the sample to a concentration of no more than 0.25 mg·mL-1. The limit of bacterial endotoxins was 1.0 EU·mg-1. CONCLUSION: Established method of bacterial endotoxins test is feasible for Cinepazide maleate injection.
出处 《中国药房》 CAS CSCD 北大核心 2011年第21期1998-1999,共2页 China Pharmacy
关键词 马来酸桂哌齐特注射液 细菌内毒素 鲎试剂 Cinepazide maleate injection Bacterial endotoxins Tachypleus amebocyte lysate