摘要
介绍了低变再沸器的失效原因,分析了设备结构不合理及局部出现的气液界面对设备失效的影响,提出了相应的改进措施并取得良好效果。
The failure reason of the low variable reboiler is introduced. The effect of unreasonable structure of the equipment and the gas - liquid interface appeared in the local area were analyzed. Some improvement measures were proposed and it has achieved good effects.
出处
《压力容器》
北大核心
2011年第5期62-64,共3页
Pressure Vessel Technology
关键词
低变再沸器
失效
改进措施
low variable reboiler
failure
improvement measure