摘要 目的探讨团注追踪法在下肢动脉造影中的应用价值。方法随机选取在我院接受下肢动脉造影的患者30例,其中采用团注追踪法18例,常规造影法12例,对比二者的总辐射剂量、造影图像数、对比剂用量及造影时间的差异。结果采用团注追踪法患者接受的总辐射剂量、造影图像数、对比剂用量、造影时间分别是(21.40±2.80)Gy/cm2、(30±41)幅、(26.56±6.84)ml、(3.03±1.29)min;而采用常规造影法患者分别为(55.00±4.30)Gy/cm2、(208±37)幅、(54.20±10.36)ml、(9.68±4.25)min,差异均有统计学意义(P<0.01)。团注追踪法图像运动伪影偏多,但并不影响诊断。结论在下肢动脉造影中,与常规造影法比较,团注追踪造影法对比剂用量较少、造影时间较短、患者接受的辐射剂量较少,具有一定临床应用价值。 Objective To investigate the application value of bolus chase method in lower extremity angiography.Methods Thirty patients underwent lower extremity angiography,18 using the bolus chase method,the other 12 using the routine method.Total dose radiation,the amount of acquired images,the amount of used contrast medium and the operation time were compared between two methods.Results The total dose radiation,acquired images,amount of used contrast medium and operation time of the bolus chase method was(21.40±2.80)Gy/cm2,30±41,(26.56±6.84)ml,(3.03±1.29)min respectively,while of the routine method was(55.00±4.30)Gy/cm2,208±37,(54.2±10.36)ml,(9.68±4.25)min,respectively.The differences were statistically significant(all P0.01).Images produced by bolus chase method had more motion artifacts,but did not influence diagnosis.Conclusion Compared with routine method,the bolus chase method needs less contrast medium,less operation time and less radiation dose in lower extremity angiography,therefore has important clinical value.
出处 《中国介入影像与治疗学》 CSCD 2011年第3期240-242,共3页 Chinese Journal of Interventional Imaging and Therapy
基金 2008年度广东省医学科研基金
关键词 下肢 血管造影术 团注追踪法 Lower extremity Angiography Bolus chase
  • 相关文献

参考文献8

  • 1Winterer JT, Schaefer O, Uhrmeister P, et al. Contrast en- hanced MR angiography in the assessment of relevant stenoses in occlusive disease of the pelvic and lower limb arteries: diagnostic value of a two-step examination protocol in comparison to conventional DSA. Eur J Radiol, 2002,41 (2):153-160.
  • 2Ashleigh RJ, Hufton AP, Razzaq R, et al. A comparison of bolus chasing and static digital subtraction arteriography in peripheral vascular disease. Br J Radiol, 2000,73(872):819-824.
  • 3陈忠伟,徐孝波,袁国裕,沈永康,傅立军,陶永军,郑善军.介入放射治疗程序中剂量学调查[J].中华放射医学与防护杂志,2006,26(5):542-543. 被引量:4
  • 4Gosch D, Ratzmer A, Berauer P, et al. Influence of grid control and object detection on radiation exposure and image quality using mobile C-arms-first results. Rofo, 2007,179(9) :896-900.
  • 5Ashleigh RJ, Hufton AP, Razzaq R, et al. A comparison of bolus chasing and static digital subtraction arteriography in peripheral vascular disease. Br J Radiol, 2000,73(872) :819- 824.
  • 6葛雅丽,李科,郑敏文,魏梦琦,张劲松,赵海涛,宦怡,韩月东.MRI移床跟踪造影扫描技术在腹、盆腔和下肢动脉疾病中的应用[J].中国医学影像技术,2002,18(11):1186-1188. 被引量:8
  • 7Ma G, Yu D, Cai Z, et al. Contrast-induced nephropathy in postmeno- pausal women undergo-ing pereutaneous coronary intervention for acote myocardial infarction. Tohoku J Exp Med, 2010,221(3):211-219.
  • 8Krummel T, Failer AL, Bazin D, et al. Contrast-induced nephropathy. Presse Med, 2010,39(7-8) :807-814.

二级参考文献7

  • 1[1]Martin RP, Thomas MG, Jorg FD. 3D Contrast MR angiography[M]. Springer,1999.124.
  • 2[2]Sueyoshi E, Sakamoto I, Matsuoka Y, et al. Symptomatic peripheral vascular tree stenosis. Comparison of subtracted and nonsubtracted 3D contrast-enhanced MR angiography with fat suppression[J]. Acta Radiol, 2000,41(2):133-138.
  • 3[3]Ho KY, Leiner T, de Haan MW, et al. Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography[J]. Radiology,1998,206(1):683-692.
  • 4[4]Quinn SF, Sheley RC, Semonsen KG, et al. Aortic and lower-extremity arterial disease: evaluation with MR angiography versus conventional angiography[J]. Radiology,1998,206(1):693-701.
  • 5[5]Koelemay MJ, Lijmer JG, Stoker J, et al. Magnetic Resonance Imaging for the Evaluation of Lower Extremity Arterial Disease: A Meta-analysis[J]. JAMA, 2001, 285(10):1338-1345.
  • 6[6]Ho VB, Choyke PL, Foo TK, et al. Automanted bolus chase peripheral MR angiography: initial practical experience and future directions of this work-in-progress[J]. J Magn Reson Imaging, 1999,10(3):376-388.
  • 7[7]Ruehm SG, Zimny K, Debatin JF. Direct contrast-enhanced 3D MR venography[J]. Eur Radiol,2001,11(1)102-112.