摘要 采用毛细管柱测定水中9种痕量硝基苯类化合物、二氯甲烷富集水中硝基苯类化合物,以及转相,电子捕获检测器检测,整个分析过程14min,各组分方法检出限达0.003~0.010μg/L,中、低浓度水样各组份的回收率在93.2%~107%之间,相对标准偏差在4.09%~6.05%之间,满足《地表水环境质量标准》(GB3838-2003)中9种硝基苯类化合物的检测要求。 Through capillary column,methylene chloride concentration,phase conversion and electron capture detector,we measured 9 kinds of trace nitrobenzene in water.The whole process is about 14 minutes.The detection limit of each component is 0.003~0.010μg/L; the recovery of in low concentrations in water samples in each group is during in 93.2%to 107%,the relative standard deviation is during 4.09%to 6.05%,which conforms to testing requirements of 9 kinds of trace nitrobenzene in surface water quality standards(GB3838- 2003).
作者 陈大兴 靳燕
出处 《石油化工应用》 CAS 2011年第5期86-88,共3页 Petrochemical Industry Application
关键词 硝基苯类 气相色谱 定量分析 nitrobenzene gas chromatography quantitative analysis
  • 相关文献

参考文献5

  • 1水质硝基苯类化合物的测定气相色谱法(HJ592-2010)[S].北京:中国环境科学出版社,2010.
  • 2中华人民共和国地表水环境质量标准(GB3838-2002)[S].北京中国标准出版社,2002.
  • 3中华人民共和国生活饮用水标准检验方法(GB/T5750-2006)[M].北京:中国标准出版社,2006.
  • 4魏复胜,寇洪茹.水和废水监测分析方法(第四版)[M】.北京中国环境科学出版社,2002.
  • 5王若苹.固相微萃取-毛细管气相色谱法快速同步分析水中硝基苯类及氯苯类化合物[J].中国环境监测,2005,21(6):15-19. 被引量:40

二级参考文献20

  • 1Magdic S Boy—Boland A.用固相微萃取分析环境试样中的有机磷杀虫剂[J].J Chromatogr A,1996,736(1):219-228.
  • 2Shirey R E.用固相微萃取(SPME)和窄孔毛细管柱快速分析环境试样[J].J High Resolut Chromatogr,1995,18(8):495-499.
  • 3Nilsson T Pelusio F.分析饮水中挥发性有机化合物的固相微萃取的评价[J].J High Resolut Chromatogr,1995,18(10):617-624.
  • 4Pan L Adams M.用固相微萃取法测定水中脂肪族酸[J].Anal Chem,1995,67(23):4396-4403.
  • 5ArthurCL PotterDW.固相微萃取用于水的直接分析理论和实践[J].现代科学仪器,1995,(2):56-57.
  • 6EISERT R,LEVSEN K.Application of sohd-phase microextraction and gas chromatography with electroncapture and mass spectrometric detection for the determination of hexachlorocychohexanes in soil solutions[J].J ChromatogrA,1994,687:133.
  • 7EISERT R,LEVSEN K,WUNSCH G.Element-selective detection of pestidcides by gas chromatography-atomic emission detection and solid-phase microextraction[J].JChromatogr A,1994,683:175.
  • 8CHEN J,Pawliszyn.Solid-phase microextraction coupled to high-performance liquid chromatography[ J ].1995,67 (15)2530-2533.
  • 9JINNO K,MURAMATSU T,SAITO Y,etal.Analysis of pescitides in environmental water samples by solid-phase microextraction-high-performance liquid chromatography[ J ].J Chromatogr A,1996,754(1-2):127-135.
  • 10Arthur CL,Killam LM.用固相微萃取分析地下水中取代苯化合物[J].Environ Sci Technol,1992,26(5):979-983.