摘要
按照《固定污染源烟气排放连续监测技术规范》(HJ/T75-2007)的要求,以Testo350XL为例,介绍了便携式烟气分析系统在燃煤电厂CEMS比对监测的流程,并分析了在实际监测中遇到的问题,提出了需要注意的事项。
According to H J/T75-2007 Specifications for Continuous Emissions Monitoring of Flue Gas Emitted from Stationary Sources, the application of portable gas analysis system in the area of CEMS in coal-fired power plant was introduced. By analyzing the problems in practical monitoring with Testo 350XL, the items to be pay attention to were put forward.
出处
《三峡环境与生态》
2011年第3期40-42,共3页
Environment and Ecology in the Three Gorges
关键词
烟气分析
电厂
烟气排放连续监测系统
gas analysis
power plant
continuous emission monitoring system