期刊文献+

三维透视断层成像导航下微创治疗髋臼骨折初步报道 被引量:3

MINIMAL INVASIVE FIXATION FOR ACETABULAR FRACTURE WITH THREE DIMENSIONAL FLUORO-IMAGES BASED ON NAVIGATION
原文传递
导出
摘要 目的探讨术中三维透视断层成像导航下髋臼骨折微创治疗的安全性及临床疗效。方法 2008年8月-2010年1月,对12例无明显移位的髋臼骨折患者采取三维透视断层成像导航下经皮微创螺钉内固定治疗。其中男7例,女5例;年龄28~57岁,平均38.1岁。致伤原因:交通事故伤9例,高处坠落伤3例。骨折按AO分型:A2.2型1例,A2.3型3例,A3.2型2例,A3.3型2例,B2.2型1例,B3.2型1例,C2.1型1例,C2.3型1例。伤后至入院时间为4 h~3 d,平均1.2 d。结果术中共植入空心螺钉28枚,平均每枚植入时间为24.8 min。除1枚空心螺钉因术中采集图像时出现较大偏差,需重新植入,余均一次性准确植入,成功率为96.4%。术中三维透视断层成像验证所有螺钉均未突入关节间隙,与术后CT扫描结果一致。术后切口均Ⅰ期愈合,无内固定失败。12例均获随访,随访时间7~24个月,平均16.8个月。末次随访X线片示骨折均愈合,螺钉植入位置满意。结论术中三维透视断层成像导航下对无明显移位的髋臼骨折进行经皮微创螺钉内固定,可有效重建髋臼关节面的平整性,提高螺钉植入的精确度,减少切口长度及出血量,降低手术对患者的损伤,减少术后并发症,有利于患者功能康复。 Objective To evaluate the security and effectiveness of minimal invasive fixation with three dimensional(3D) fluoro-images based on navigation system in the management of acetabular fractures.Methods Between August 2008 and January 2010,12 patients with acetabular fractures were treated with percutaneous screw fixation under the guidance of 3D fluoro-images based on navigation system after closed reduction.There were 7 males and 5 females,aged 28-57 years(mean,38.1 years).Fractures were caused by traffic accident in 9 cases,and falling from height in 3 cases.According to AO classification,there were 1 case of A2.2 type,3 cases of A2.3 type,2 cases of A3.2 type,2 cases of A3.3 type,1 case of B2.2 type,1 case of B3.2 type,1 case of C2.1 type,and 1 case of C2.3 type.The interval from injury to hospitalization was 4 hours to 3 days(mean,1.2 days).Results Totally 28 screws were implanted.The average time to implant 1 screw was 24.8 minutes.Twenty-seven screws were placed correctly with a successful rate of 96.4%,only 1 screw was reinserted for deviation.All the screws were checked by the 3D fluoro-images,which showed they were not in the joint space after fixation.The results were the same as that by CT scanning.Incisions healed by first intention,and no implant failure occurred.All 12 patients were followed up 7 to 24 months with an average of 16.8 months.At last follow-up,fracture union was achieved in all patients with satisfactory screw fixation.Conclusion The minimal invasive fixation with 3D fluoro-images based on navigation system makes the surgery for the nondisplaced acetabular fracture more precise and time-saving,minimizes the surgery injury,and improves the clinical results with less complications.
出处 《中国修复重建外科杂志》 CAS CSCD 北大核心 2011年第5期517-520,共4页 Chinese Journal of Reparative and Reconstructive Surgery
关键词 髋臼骨折 微创技术 三维透视断层成像 导航技术 Acetabular fracture Minimal invasive technology Three dimensional fluoro-image Navigation technology
  • 相关文献

参考文献21

  • 1Helfet DL, Borrelli J Jr, DiPasquale T, et al. Stabilization of acetabular fractures in elderly patients. J Bone Joint Surg (Am), 1992, 74(5): 753-765.
  • 2Routt ML Jr, Simonian PT, Grujic L. The retrograde medullary superior pubic ramus screw for the treatment of anterior pelvic ring disruptions: a new technique. J Orthop Trauma, 1995, 9(1): 35-44.
  • 3Kaempffe FA, Bone LB, Boredr JR. Open reduction and internal fixation of acetabular fractures: heterotopic ossification and other complications of treatment. J Orthop Trauma, 1991, 5(4): 439-445.
  • 4Mouhsine E, Garofalo R, Borens O, et al. Percutaneous retrograde screwing for stabilization of acetabular fractures. Injury, 2005, 36 (11 ): 1330-1336.
  • 5Starr AJ, Jones AL, Reinert CM, et al. Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum. Injury, 2001, 32 Suppl 1: SA45-50.
  • 6Parker PJ, Copeland C. Percutaneous fluoroscopic screw fixation of acetabular fractures. Injury, 1997, 28(9-10): 597-600.
  • 7Starr AJ, Reinert CM, Jones AL. Percutaneous fixation of the columns of the acetabu|um: a new technique. J Orthop Trauma, 1998, 12(1): 51-58.
  • 8Carmack DB, Moed BR, McCarroll K, et al. Accuracy of screw penetration of the acetabulum with intraoperative fluoroscopy and computed tomography. J Bone Joint Surg (Am), 2001, 83-A(9): 1370-1375.
  • 9Lin YC, Chen CH, Humig HT, et al. Percutaneous antegrade screwing for anterior column fracture of acetabulum with fluoroscopic-based computerized navigation. Arch Orthop Trauma Surg, 2008, 128(2): 223 -226.
  • 10Przkora R, Bosch U, Zelle B, et al. Damage control orthopedics: a case report. J Trauma, 2002, 53(4): 765-769.

二级参考文献19

  • 1杨永宏,郑杰.计算机辅助导航系统及其骨科应用[J].中华创伤骨科杂志,2005,7(7):614-616. 被引量:20
  • 2王满宜,王军强,王田苗.加强计算机辅助骨科手术的基础研究,稳步推进临床应用[J].中华医学杂志,2006,86(9):589-591. 被引量:5
  • 3Nelson DW, Duwelius PJ. CT-guided fixation of sacral fractures and sacroiliac joint disruptions. Radiology, 1991,180:527-532.
  • 4Tonetti J, Carrat L, Lavalle'e S, Pittet L, Merloz P,Chirossel JP. Percutaneous iliosacral screw placement using image guided techniques. Clin Orthop, 1998, (354):103-110.
  • 5Crowl AC, Kahler DM. Closed reduction and percutaneous fixation of anterior column acetabular fractures. Comput Aided Surg, 2002, 7:169-178.
  • 6Brown GA, Willis MC, Firoozbakhsh K, Barmada A, Tessman CL, Montgomery A. Computed tomography image guided surgery in complex acetabular fractures. Clin Orthop, 2000,(370):219-226.
  • 7Langlotz F, Nolte LP. Computer-assisted orthopaedic surgery: from theory to the operating room. Tech Orthop, 2003, 18:140-148.
  • 8Kahler DM. Image guidance: fluoroscopic navigation. Clin Orthop, 2004, (421):70-76.
  • 9Tonetti J, Carrat L, Lavalle S, et al. Percutaneous iliosacral screw placement using image guided techniques. Clin Orthop Relat Res, 1998, 354: 103-110.
  • 10Crowl AC, Kahler DM. Closed reduction and percutaneous fixation of anterior column acetabular fractures. Comput Aided Surg, 2002, 7:169-178.

共引文献36

同被引文献31

  • 1王庆贤,张英泽,潘进社,李亚洲,刘向东,薛静.髋臼后柱拉力螺钉内固定的应用解剖学[J].中国临床解剖学杂志,2004,22(6):596-598. 被引量:26
  • 2王亦璁.骨与关节损伤[M].北京:人民卫生出版社,2010:17-18.
  • 3苗华,周健生.骨科手术人路解剖学[M].合肥:安徽科学技术出版社,2011:523.
  • 4危杰,刘墦,吴新宝,等主译.骨折治疗的A0原则[M].上海:上海科学技术出版社,2010:464.
  • 5Broberg M A,Morrey B F. Results of delayed excision ofthe radial head after fracture [J]. J Bone Joint Surg(Am),1986,68(5):669-674.
  • 6Yi C, Burns S, Hak DJ. Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery[J] . J Orthop Trauma, 2014, 28(1): 48-56.
  • 7Mu WD, Wang XQ, Jia TH, et al. Quantitative anatomic basis of antegrade lag screw placement in posterior column of acetabulum[J]. Arch Orthop Trauma Surg , 2009, 129(11): 1531-1537.
  • 8Xu P, Wang H, Liu ZY, et al. An evaluation of three-dimensional imageeguided technologies in percutaneous pelvic and acetabular lagscrew placement[J]. J Surg Res, 2013, 185(1): 338-346.
  • 9Shazar N, Eshed I, Ackshota N, et al. Comparison of acetabular fracture reduction quality by the ilioinguinal or the anterior intrapelvic (modified Rives-Stoppa) surgical approaches[J] . J Orthop Trauma, 2014, 28(6): 313-319.
  • 10Archdeacon MT. Comparison of the ilioinguinal approach and the an- terior intrapelvic approaches for open reduction and internal fixation of the acetabulum[J]. J Orthop Trauma, 2015, 29 Suppl 2: S6-S9.

引证文献3

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部