微型种植体支抗-骨界面压力侧和非压力侧的组织学研究 被引量:8

A histological study on the bone-implant interface of the mini-screw implant anchorage
原文传递
导出
摘要 目的 研究在不同愈合时间和负载条件下微型种植体支抗-骨界面压力侧和非压力侧的组织学变化.方法 选用纯种Beagle犬8只,在其上颌根间牙槽骨中植入86颗微型种植体支抗,分别进行即刻负载、愈合2周、愈合4周、愈合12周后加载150 g和300 g牵引力,定期注射荧光标志物,加载2个月后处死动物.标记种植体的压力侧和非压力侧,两侧分别进行种植体颈部骨结合率(BIC)、骨充填率(BSA)和矿物沉积率(MAR)的测量以及HE染色组织形态观察,以BIC和BSA作为骨整合能力的观察指标.结果 即刻负载组和愈合2周负载300克组压力侧的骨整合能力、矿物沉积率和骨改建活跃程度均小于非压力侧,其余各组则相反.不同负载力值组间比较无显著性差异.结论 微型种植体支抗-骨界面颈部即刻负载时压力侧的骨整合和骨改建较非压力侧低,随着愈合时间的延长,压力侧相对增强,非压力侧相对降低,而负载力值对界面的影响较小. Objective To investigate the histological difference at the bone-implant interface between pressure and non-pressure sides of the mini-screw implant anchorage (MIA) under the condition of different loading force and heeling time. Methods Eighty-six MIAs were inserted in the maxillary alveolar bone between the dental roots in 8 beagles. Healing after 0, 2, 4, 12 weeks, 150 g and 300 g forces were loaded perpendicularly to the implants and fluorochrome was injected. Two months later, all dogs were sacrificed. The slices of MIA on the pressure and non-pressure sides were labeled. Bone implant contact ratio(BIC), bone surface area(BSA) and mineral apposition rate (MAR) were measured and histological observations were carried out. Results BIC, BSA, MAR and bone remodeling on the pressure side were lower than those on the non-pressure side in the immediate loading group and the group healing after 2 weeks with 300 g force, while the reverse result was observed in the rest of the groups. No significant difference was found between the two different force loading groups. Conclusions Bone integration and remodeling on the pressure side of MIA-bone interface was lower than those on the non-pressure side in the immediate loading group. With the healing time, it was relatively increased on the pressure side while decreased on the non-pressure side.
出处 《中华口腔正畸学杂志》 2011年第1期27-31,共5页 Chinese Journal of Orthodontics
基金 上海市重点学科(优势学科)建设项目(Y0203)
关键词 种植体支抗 骨整合 组织学 Mini-screw implant anchorage (MIA) Osteointegration Histology
  • 相关文献

参考文献19

  • 1Kim SH,Kook YA,Jeong DM,et al.Clinical application of accelerated osteogenic orthodontics and partially osseointegrated mini-implants for minor tooth movement.Am J Orthod Dentofacial Orthop,2009,136(3):431-439.
  • 2Chen Y,Lee JW,Cho WH,et al.Potential of self-drilling orthodontic microimplants under immediate loading.Am J Orthod Dentofacial Orthop,2010,137(4):496-502.
  • 3Cornelis MA,Scheffler NR,De Clerck HJ,et al.Systematic review of the experimental use of temporary skeletal anchorage devices in orthodontics.Am J Orthod Dentofacial Orthop,2007,131 (4 Suppl):S52-58.
  • 4Park YS,Yi KY,Moon SC,et al.Immediate loading of an implant following implant site development using forced eruption:a case report.Int J Oral Maxillofac Implants,2005,20(4):621-626.
  • 5Costa A,Raffaini M,Melsen B.Microscrew as orthodontic anchorage:a preliminary report.Int J Adult Orthognath Surg,1998,13(4):201-209.
  • 6Kyung HM,Park HS,Bae SM,et al.Development of orthodontic micro-implants for intraoral anchorage.J Clin Orthod,2003,37(6):321-328.
  • 7Ma JQ,Zhang WB,Wang L,et al.Stability and bone response ofimmediately loading micro-implants in beagle dogs.Int J Oral Maxillofac Implants,2008,23 (5):885-890.
  • 8张月兰,余炜伟,崔淑霞,蔡留意,刘进忠,王世昌.正畸微植体支抗即刻负载后微植体-骨界面的组织形态学变化[J].郑州大学学报(医学版),2009,44(5):977-980. 被引量:5
  • 9Piattelli A,Scarano A,Quaranta M.High-precision costeffective cutting system for producing thin sections of oral tissues containing dental implants,Biomaterials,1997,18(7):577-579.
  • 10Lopes Cde C,K(o)ning Júnior B.Histological findings of bone remodeling around smooth dental titanium implants inserted in rabbit's tibias.Ann Anat,2002,184(4):359-362.

二级参考文献11

  • 1周洪,叶湘玉.骨融性种植体对持续性正畸力反应的实验研究[J].中华口腔正畸学杂志,1995,11(4):149-151. 被引量:1
  • 2马俊青,王林,张卫兵,王震东,严斌.微型支抗种植体即刻加载的界面研究[J].中华口腔医学杂志,2005,40(1):41-41. 被引量:17
  • 3石咏梅,王翔,王虎中,郭家平,王早堂.微螺钉支抗种植体与颌骨愈合形式探讨[J].临床口腔医学杂志,2005,21(5):278-280. 被引量:9
  • 4Albrektsson T,et al.Bone-mental interface in osseointegration[J].Prosthet Dent,1987,57(5):597-607.
  • 5Bra nemark PI.Ossointegrated implants as orthodontic anchorage in the treatment of partially edentulous adult patients[J].Eur Orthod,1994,16(3):187.
  • 6Roberts WE,Helm FR,Marshall KJ,Gongloff RK.Rigid endosseous implants for orthodontic orthopedic anchorage[J].Angle Orthod,1989,59:247-256.
  • 7Roberts WE,Marshal KJ,Mozsarg PG.Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site[J].Angle Orthod,1990,60:135-152.
  • 8Wehrbein H,Diedrich P.Enclosseous titanium implants during and after orthodontic load an experimental study in the dog[J].Clinoral Impl Res,1993,4:76.
  • 9Odman J,Lekholm U,Jem T,et al.Osseointegrated implants as orthodontic anchorage in the treatment of partially edentulous adults patients[J].Eur Orthod,1994,16:187.
  • 10Smalley WM,Shapiro PA,Hohl TH.Osseointegrated titanium implants for maxillofacial protraction in monkeys[J].Am Orthod Dentofac Orthop,1988,94:285.

共引文献10

同被引文献61

引证文献8

二级引证文献79

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部