摘要 介绍了一种故障录波数据集中分析系统,给出了一种比较实用的联网方案,解决了不同厂家的不同型号录波器的联网和数据远传问题,并提供了单端和非同步数据的双端精确测距算法,保护、断路器。 In this paper ,a software of centralized analysis and expert system on the fault recorder data is introduced and a practical scheme of joining network is given.The problem of joining network for different types of fault recorders from different producers is solved by this software.In addition,fault location for single terminal and the accurate one for double terminal with unsynchronous data is provided.Besides,an expert system with the function of judging the actions for the relay protections,the breakers and the auto?reclosings as well as the powerful background analysis are offered.
出处 《中国电力》 EI CSCD 北大核心 1999年第9期40-43,共4页 Electric Power
关键词 电力系统 故障录波 数据集中分析 专家系统 fault record network communication expert system