乳腺专用PET连续采样电子学系统设计与性能测试 被引量:1

Design and Performance of Continuous Sampling Module for Positron Emission Mammography
下载PDF
导出
摘要 对乳腺专用PET进行了简单介绍,详细叙述了系统中连续采样电子学系统的设计和性能测试。该电子学采用子母板设计结构,包含了模数转换、时间数字转换和CAN控制等多个模块,具备对前端探测器模拟信号进行连续采样、处理和传输功能。实验表明,该系统能完全满足乳腺专用PET对连续采样的需求。该系统还有集成度高、通用性强、配置灵活等优点。 Design and performance of data processing electronics(continuous sampling module,CSM) for positron emission mammography(PEM) was introduced.Sub-module of ADC and TDC was allocated on daughter board and mother board of CSM,respectively.There was also a CAN controller on mother board.Continuous sampling of front-end analog signals,data processing and transmission were implemented in the design.Evaluation and performance show that the CSM is fulfilled the requirement of high-rate data processing in our PEM.The high-integrated CSM can be configured flexibly and can be extended to other system easily.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2011年第5期628-632,共5页 Atomic Energy Science and Technology
基金 国家863计划资助项目(2006AA02Z4B0) 国家自然科学基金资助项目(10775149 30872954) 天津自然科学基金资助项目(08JCZDJC23700)
关键词 乳腺专用正电子发射断层扫描仪 连续采样系统 电子学 positron emission mammography continuous sampling module electronics
  • 相关文献

参考文献1

二级参考文献8

  • 1Tang X W.Functional Imaging of the Brain. . 1999
  • 2Dahlbom M,and Homan EJ.An evaluation of a two-dimensional array detector for high resolution PET. IEEE Transactions on Image Processing . 1988
  • 3J. G. Rogers,A. J. Taylor,M. F. Rahimi,et al.An improved multicrystal 2-D BGO detector for PET, IEEE.Trans. Nursing Science . 1992
  • 4Cutler P D,Hoffman E J.Use of digital front-end electronics for optimization of a modular PET detector. IEEE Transactions on Medical Imaging . 1994
  • 5Young J W,Moyers J C,Lenox M.FPGA based front-end electronics for a high resolution PET scanner. IEEE Trans.Nucl Sci . 2000
  • 6Stronger K A,Johnson M T.Optimal calibration of PET crystal position maps using Gaussian mixture models. IEEE Transactions on Nuclear Science . 2004
  • 7Casey,ME,Nutt,R.A multislice two dimensional BGO detector system for PET. IEEE Transactions on Nuclear Science . 1986
  • 8Yoshida E,Kimura Y,Kitamura K,et al.Calibration procedure for a DOI detector of high resolution PET through a Gaussian mix-ture model. IEEE Transactions on Nuclear Science . 2004

共引文献1

同被引文献9

  • 1H Zaidi, C Thompson. Evolution and Developments in Instrumentation for Positron Emission Mammography [J]. Pet Clinics, 2009, 4(4) :317 -327.
  • 2C. J. Thompson. Feasibility study for positron emis- sion mammography [J]. MEDICAL PHYSICS, 1994,21 (4) :529 -538.
  • 3MC Abreu, JD Aguiar, F'G Almeida, et al. Design and Evaluation of the Clear - PEM Scanner for Posi- tron Emission Mammography [K]. IEEE Transactions on Nuclear Science, 2006, 53 (1) :71 - 77.
  • 4LI Lin, GU Xiao - yue, LI Dao-wu, et al. Perform- ance Evaluation and Initial Clinical Test of the Posi- tron Emission Mammography System (PEMi) [J]. IEEE Transactions on Nuclear Science, 2015, 62 (5):1 -9.
  • 5Guerra A D, Belcari N, Bisogni M G, et al. Silicon Photomultipliers (SiPM) as novel photodetectors for PET [J]. Nuclear Instruments & Methods in Physics Research, 2011, 648(17) :$232 $235.
  • 6V Popov, S Majewski, AG Weisenberger. Readout e- lectronics for multi - anode photomultiplier tubes with pad matrix anode layout [J]. IEEE Nuclear ScienceSymposium Conference Record, 2003, 567( 1 ):2156 -2159 Vol. 3.
  • 7Neves J A. The Clear PEM breast imaging scanner [J]. Nuclear Instruments & Methods in Physics Re- search A, 2011, 628(1):444-447.
  • 8Moadel R M. Breast cancer imaging devices [J]. Seminars in Nuclear Medicine, 2011, 41 ( 3 ) : 229 241.
  • 9Li L, Gu X, Li D, et al. Ability of the Positron E- mission Mammography system, PEMi, in detection of millimeter- sized lesions [C]// Nuclear Science Symposium and Medical Imaging Conference (NSS/ MIC), 2013 IEEE. IEEE, 2013:1 -7.

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部