摘要
介绍了漳泽电厂 3 号炉调节受热面频繁爆管情况, 对爆管原因进行了分析, 提出了改进方案, 并根据改进后的试验研究结果, 提出几点建议。
The frequent tube explosion at the adjusting heating surface of No 3 bolier in Zhangze Electric Power Ltd.Co.is introduced.Causes of the explosion is analysed and corresponding improvement proposed. Besides,a few points of suggestions are presented according to the test results of the improvement.
关键词
锅炉
受热面
爆管
电厂
Adjusting Heating Surface Tube Explosion Improvement Test and Study