摘要 目的:探讨128层螺旋cT血管成像技术对原发性蛛网膜下腔出血的临床诊断价值。方法:应用128层螺旋CT机,对126例CT平扫诊断为原发性蛛网膜下腔出血的患者进行颈脑血管成像检查,用德国西门子公司SyngoNeuroDSA软件系统行多技术处理,回顾性分析其影像学表现,并行DSA检查对照分析。结果:128层螺旋CT显示89例动脉瘤,5例动静脉畸形,32例未见异常。89例动脉瘤患者中38例行DSA检查,病变部位与病变形态与128层螺旋CT显示一致;32例未见异常者中,8例行DSA检查,发现3例有动脉瘤,5例为阴性。结论:128层螺旋CT血管成像技术是检查原发性蛛网膜下腔出血的首选方法,具有无创性、高效性,在一定程度上可以代替常规DSA检查。 Objective :To investigate the diagnostic value of 128 slice spiral CT angiography for primary subarachnoid hemorrhage, nethods:126 patients diagnosed as primary subarachnoid hemorrhage by non -contrast CT were performed by CTA. The reconstruction images were analyzed retrospectively with Siemens Syngo Neuro DSA software systems, the DSA and surgery results were compared. Results:Among the 126 cases, 89 cases of aneurysms were detected, 5 cases arteriovenous fistula were displayed, 32 cases without anomalies ( Among the 32 cases, 8 cases were performed DSA, 3 cases showed aneurysms, 5 cases were still negative). Conclusions : 128 slice spiral CT angiography is the first choice for detecting the causes of primary subarachnoid hemorrhage because it is non - invasive and highly effective, and to some extent, it can replace conventional DSA.