从分析转炉烟气洗涤污水水质入手,结合武钢实际,从理论和实践的结合上,详细论述了采用碳酸钠软化法处理转炉烟气洗涤污水的原理、方法、水质控制标准及运行管理中应该注意的几个问题。
Proceeding from analysis on the quality of the converter fume flushing waste water,in light of the actual condition in WISCO and in combination of the theory with practice the present paper discusses in detail the principle, procedure and control criteria of the process for treatment of the converter fume flushing waste water with Na 2CO 3 and questions that need to be taken care of in the production and management. The process proves to be worthy of application and popularization.
出处
《武钢技术》
CAS
1999年第5期54-57,64,共5页
Wisco Technology
关键词
转炉烟气洗涤水
碳酸钠软化
循环利用
污水处理
converter fume flushing water softening with sodium carbonate recycling utilizationControls$$$$ Tan Xiao Abstract:On the basis of the experimental research of the numberical PID conbols, this paper has introduced some steps and ways on h