期刊文献+

高炉炉底侵蚀线的计算 被引量:5

Calculation on the erosion boundary of the blast furnace bottom
下载PDF
导出
摘要 针对梅山3# 高炉炉底条件,用有限元素法开发了只依靠热电偶测得的温度作为边界条件和修正温度,对炉底侵蚀情况进行在线监测的二维数学模型,解决了采用炉底及炉侧的对流边界条件难以实时检测的问题- 模型中采用网格变形拟合的方法处理边界移动的问题,算法简单便于在线运行- 通过梅山3 # 高炉的实际应用及对不同侵蚀状态的计算。 An on line monitoring mathematical model for Meishan No.3 BF with FEM method is developed. This model only uses the temperatures measured as boundary conditions and the verifying temperature,with no consideration of convective condition of side wall and bottom of BF. The method with the net shape changing to fit the corrosion curve is taken to solve the inner boundary moving problem. Through the on line application of this model on Meishan No.3 BF and calculation with hypothetical abnormal data, the results are satisfactory.
出处 《包头钢铁学院学报》 1999年第3期199-203,共5页 Journal of Baotou University of Iron and Steel Technology
关键词 高炉 炉底侵蚀线 有限元 数学模型 计算 blast furnace hearth bottom erosion finite element method mathematical model
  • 相关文献