期刊文献+

多点法机床主轴回转准确度测量系统中的关键技术 被引量:5

The Key Techniques for a Multi point Measuring System for the Error Motions of a Lathe Spindle
下载PDF
导出
摘要 本文研究多点法机床主轴回转运动准确度测量系统中的关键技术。以8阶Butterworth滤波器MAX291为核心改进了电容测微仪系统的动态测量电路,改进后的电容测微仪在±10μm的量程内,非线性误差最大不超过0.8%,重复性准确度优于0.15%,测量准确度优于0.1μm,频响范围达4.2kHz。研究了电容测微仪动态灵敏度及线形度的测试与标定方法。 Thekeytechniquesforamulti\|pointmeasuringsystem for the error motions of a lathe spindle are studied in thispaper.Theimprovedcapacitancemicrometerwith high accuracy and frequency response has been developed,which dynamic measuring circuit adopts an 8\|order Butterworth filter as the key device.The frequency response range of the improved capacitance micrometer is up to 4.2kHz,the maximal relative non repeatability and the non linearerrorsarelessthan0.15% and 0.8% respectively,and the measurement accuracy is better than 0.1μm within ±10μm.The test and calibration methods of the dynamic characteristics of the capacitance micrometer are proposed.A practical measuring system of multi\|channel simultaneous data sampling has been developed.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 1999年第5期526-528,540,共4页 Chinese Journal of Scientific Instrument
基金 高等学校博士学科点专项科研基金
关键词 动态测量 准确度 机床 主轴 多点法 Dynamic measurement\ Capacitance micrometer\ Frequency response\ Accuracy\ Calibration
  • 相关文献

参考文献8

  • 1焦贵福.机床回转轴回转精度的评价方法[J].组合机床与自动化加工技术,1993(5):10-20. 被引量:3
  • 2张宇华.圆度及轴系测量误差分离与补偿技术的研究:学位论文[M].天津:天津大学精密仪器与光电子工程学院,1996..
  • 3强锡富.几何量电测量仪[M].机械工业出版社,1978..
  • 4Zhang G X,Ann CIRP,1997年,46卷,1期,441页
  • 5张宇华,学位论文,1996年
  • 6Zhang G X,Ann CIRP,1993年,42卷,1期,593页
  • 7焦福贵,组合机床与自动化加工技术,1993年,5期,10页
  • 8强锡富,几何量电测量仪,1978年