摘要 通过对裂纹模拟缺陷试件的数字透射成像检测试验,分析并研究了面阵探测器成像检测系统、透照参数、检测工艺与检测图像质量的关系,并给出了检测过程中应该注意的问题。具体试验表明:面阵探测器X射线数字成像系统在一定厚度范围内的检测效果(主要是图像的单丝像质计指数)优于同厚度的射线照相B级要求。 Through the simulation of crack defects of digital transmission imaging specimens, array detector imaging detection system, parameter, test process and the quality of images were analyzed and investigated, the points which should be paid attention to in the detection process were given. Experiments showed that the results prinmarily the rends of the image quality indication of single acquired by array detector X-ray digital imaging system within a certain thickness range were better than by the industrial radiography B level requirement within the same thickness.
出处 《无损检测》 2011年第5期32-34,共3页 Nondestructive Testing
基金 国防科技工业技术基础科研课题基金资助项目(T2007A001)
关键词 面阵列探测器 数字透射成像 检测参数 图像质量 Flat detector Digital transmission imaging Parameter Image quality
  • 相关文献

参考文献2

二级参考文献5

  • 1梁丽红,路宏年.射线面阵探测器成像系统校正研究[J].光子学报,2004,33(10):1277-1280. 被引量:4
  • 2Richard L Weisfield, Mark A Hartney, Robert A Street, et al. New amorphous-silicon image sensor for X-ray diagnostic medical imaging applications[J]. Proc of SPIE, 1998,3336: 444-452.
  • 3Hoheisel M, Arques M, et al. Amorphous silicon X ray detectors[J]. Journal of Non-Crystaline Solids,1998,227(5): 1300-1305.
  • 4Hamers S, Freyschmidt J. Digital radiography with an electronic flat-panel detector: First clinical experience in skeletal diagnostics[J]. Medica Mundi, 1998, 42(3) :1-6.
  • 5孔凡琴,贾磊.基于加权减影的非等厚工件的X射线检测[J].光学技术,2003,29(5):590-591. 被引量:1