口腔放射中报废成像板的改造利用 被引量:1

Modification and utilization of abandoned oral radioactive image plate
下载PDF
导出
摘要 目前应用CR(computed radiography)技术进行口腔颌面医学影像检查被广泛应用。作为CR技术的核心组件-成像板(image plate,IP)承载着重要作用。其易磨损及划伤势必会影响成像效果,也缩短了使用寿命。笔者在操作中利用一些常用的工具对IP加以改造,使其能达到理想的使用寿命,而且摄取的影像更加清晰。 Computed radiography (CR) technology is widely used to obtain maxillofacial radiograph. As the core component, image plate (IP) plays an important role in CR technology. However, IP is liable to be abraded and scuffed, the service life of IP is limited. Accordingly, We modified IP, prolonged the service life of IP and increased the resolution of radiograph.
作者 黄朝辉
出处 《实用口腔医学杂志》 CAS CSCD 北大核心 2011年第3期413-415,共3页 Journal of Practical Stomatology
关键词 口腔放射 改造利用 成像板 牙片 工具 Oral radiological technology Modification Image plate Dental film Equipment
  • 相关文献

参考文献5

二级参考文献27

  • 1董敏俊,王韶颖,石慧敏.多层螺旋CT在上颌埋伏牙定位中的应用[J].中国医学影像技术,2005,21(5):707-708. 被引量:7
  • 2乔文龙,黄惠如.数字X线摄影及其临床应用[J].中国医疗器械杂志,1996,20(2):98-99. 被引量:10
  • 3张燕,吴士英.牙根纵裂61例诊断分析[J].牙体牙髓牙周病学杂志,1997,7(2):123-123. 被引量:11
  • 4[1] Versteeg KH,Sanderink GC, Velders XL, et al. In vivo study of approximal caries depth on storage phosphor plate images compared with dental X-ray film. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 1997,84(2):210
  • 5[2] Moystad A, Svanaes DB, Risnes S, et al. Detection of approximal caries with a storage phosphor system:a comparison of enhanced digital images with dental X-ray film. Dentomaxillofac Radiol, 1996,25:202
  • 6[3] Svanaes DB, Moystad A, Risnes S, et al. Intraoral storage phosphor radiography for approximal caries detection and effect of image magnification. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 1996,82(1):94
  • 7[4] Wenzel A, Gotfredsen E, Borg E, et al. Impact of lossy image compression on accuracy of caries detecion in digital images taken with a storage phosphor system. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 1996,81(3):351
  • 8[5] Wenzel A, Borg E, Hintze H, et al. Accuracy of caries diagnosis in digital images from charge-coupled device and storage phosphor systems:an in vitro study. Dentomaxillofac Radiol, 1995,24:250
  • 9[6] Borg E, Grondahl HG. A comparison of image quality in filim, charge-coupled device and storage phosphor systems. Dentomaxillofac Radiol, 1996,25:82
  • 10[7] Nielsen LL, Hoernoe M, Wenzel A. Radiographic detection of cavitation in approximal surfaces of primary teeth using a digital storage phosphor system and conventional film, and the relationship between cavitation and radiographic lesion depth: an in vitro study. Int J paediatr Dent, 1996,6(3):167

共引文献25

同被引文献7

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部