摘要
采用不同等离子体清洗工艺对镁基金属样品进行清洗,随后磁控溅射沉积纯Cr镀层。利用SEM、划痕仪分析了不同等离子体清洗工艺下镁基金属的表面形貌与膜/基结合强度的变化。结果表明,过高的清洗偏压作用下,基体表面会产生深径比>0.5的孔洞状结构缺陷;过长清洗时间后,离子轰击产生的能量积淀效应使基体表面温升显著,局部区域出现熔融、烧结现象,二者均使后续沉积镀层结合强度变低。
Mg alloy substrate samples were cleaned at different plasma cleaning process and pure Cr coatings were deposited using magnetron sputtering technique.Surface micrographs of Mg alloy substrate and adhesion strength of the coatings were analyzed by SEM and scratch tester.The results show that:the substrate surface is shown the deep-hole diameter is greater than 0.5-like structural defects owing to excessive cleaning voltage.After long time cleaning the energy accumulation effect generated the temperature increase significantly by the ion bombardment of the substrate surface and the local region shown the melting,sintering phenomenon.Both of them made the adhesion strength of following accumulated coatings decreased.
出处
《功能材料》
EI
CAS
CSCD
北大核心
2011年第6期1127-1129,1133,共4页
Journal of Functional Materials
基金
国家高技术研究发展计划(863计划)资助项目(2005AA33H010)
关键词
等离子体清洗
镁合金
表面形貌
结合强度
plasma cleaning
Mg alloy
surface morphology
adhesion strength