介绍了配电自动化系统两种主站的两种设置方式。重点介绍配电自动化二级主站的功能和作用。讨论了使用二级主站构成的配电自动化系统方案及其特点。最后,简单介绍了国外应用二级主站实施配电自动化的案例。
The two level schemes of master station of distribution automation are presented in this paper and the functions of a sub master station for distribution automation are emphatically described. A project of distribution automation system constituted by sub masters, in which the three basic functions such as SCADA monitoring, feeder automation control and data concentrating are provided, and its features are discussed. As an example, a suggested distribution automation scheme using sub master that might be used in Hebburn, UK, is presented.
出处
《电网技术》
EI
CSCD
北大核心
1999年第7期46-48,共3页
Power System Technology
关键词
配电自动化
馈线自动化
配电网
二级主站
distribution management system(DMS)
distribution automation(DA)
feeder Automation(FA)
master station
sub master