摘要
在以氢先氦后的顺序注入的硅样品中,经不同温度的退火,发现比氢、氦分别单独注入时小得多的注入剂量足以使硅样品表面产生砂眼及剥离。本文用RBS/C、X射线四晶衍射、AFM、XTEM 等不同方法对氢、氦共注入样品进行了研究,对结果作了计算机模拟,并对其机制做了分析与研究。
Hydrogen and then helium were implanted into Si samples. Then these samples were annealed at different temperatures. It was found that the total dose of co-implantation which cause blistering and exfoliation on the surface was much smaller than the dose of hydrogen and helium implanted separately. In this work, RBS/C (Rutherford Backscattering Spectroscopy and Channeling), X-ray Four-Crystal Diffractormeter, AFM (Atom Force Microscopy) and XTEM (Cross Sectional Transmission Electron Microscopy) were used to characterize these samples. Some results were then computer simulated and the mechanism was discussed.
出处
《功能材料与器件学报》
CAS
CSCD
1999年第3期224-228,共5页
Journal of Functional Materials and Devices
基金
全国自然科学基金
上海市科学技术发展基金
上海市启明星计划的资助