期刊文献+

动态血糖监测系统在儿童糖尿病中的应用 被引量:1

Application of continuous glucose monitoring system in children with diabetes
下载PDF
导出
摘要 动态血糖监N(cGM)是通过葡萄糖感应器监测皮下组织问液的葡萄糖浓度,全面反映患者24h血糖水平的监测技术,提供连续、可靠的全天血糖信息,分析患者血糖波动趋势,有助于发现不易被传统监测方法所探测的高血糖和低血糖。目前已有多种CGM技术应用于临床,其中动态血糖监测系统(CGMS)具有操作简单、佩戴方便、损伤小、结果准确等优点.已成为国内应用较广泛且成熟的CGM技术之一。
出处 《药品评价》 CAS 2011年第11期22-24,28,共4页 Drug Evaluation
  • 相关文献

参考文献3

  • 1Deiss D, Meyer K, Kordonouri O, et al. Long hypoglycemic periods detected by continuous glucose monitoring in very young children with diabetes[J]. J Pediatric Endocrinol Metab, 2000, 13(Suppl 4): 70.
  • 2陆忠,沈水仙,罗飞宏,支涤静,赵诸慧.儿童1型糖尿病动态血糖监测的临床意义[J].中国实用儿科杂志,2005,20(12):721-723. 被引量:14
  • 3Cobry E, Chase HE Hypoglycemic unawareness and type 1 diabetes: hope with CSII and CGM[I]. Infusystems USA, 2006, 3: 25-28.

二级参考文献10

  • 1Pakesh A,Julie AE,Karen R,et al.Hypoglycemia prevalence in prepubertal children with type 1 diabetes on standard insulin regimen:use of continuous glucose monitoring system.Diabetes Care,2003,26:662-667.
  • 2Einhorn D,Sadler C,Fink RI.New insights on glycemic control in the ambulatory setting:MinMed's continuous glucose monitoring system.Endo Society 82nd Meeting,2000,P424.
  • 3Diabetes Control and Complications Trial Research Group.The absence of a glycemic threshold for the development of long-term complications:the perspective of the diabetes control and complications trial.Diabetes,1996,45:1289-1298.
  • 4The DCCT Research Group.Hypoglycemia in the diabetes control and complications trial.Diabetes,1997,46(2):271-286.
  • 5American Diabetes Association.Standards of medical care for patients with diabetes.Diabetes Care,2000,23(Suppl 1):32-42.
  • 6The Diabetes Control and Complications Trial Research Group.The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.New Engl J Med,1993,329:977-986.
  • 7American Diabetes Association.Self-monitoring of blood glucose (consensus statement).Diabetes Care,1996,19(Suppl 1):562-566.
  • 8Gross TM,Mastrototaro JJ.Efficacy and reliability of the continuous glucose monitoring system.Diabetes Technol Ther,2000,2(Suppl 1):19-26.
  • 9Mastrototaro J.The MinMed continuous glucose monitoring system (CGMS).J Pediatr Endocrinol Metab,1999,12(Suppl 3):751-758.
  • 10Deiss D,Meyer K,Kordonouri O,et al.Long hypoglycemic periods detected by continuous glucose monitoring in very young children with diabetes.J Pediatr Endocrinol Metab,2000,13(Suppl 4):70.

共引文献13

同被引文献8

引证文献1

二级引证文献9