呼吸机相关性肺炎影响因素管理调查 被引量:6

Investigation the rish factors management of ventilator-associated pneumonia.
下载PDF
导出
摘要 目的:了解乌鲁木齐三级甲等医院呼吸机相关性肺炎相关因素管理现状,促进管理规范化、标准化。方法:采用自行设计的问卷,以乌鲁木齐三级甲等医院20名ICU护士长为研究对象,对人工气道管理、冷凝水管理、常规体位管理等进行调查。结果:合理气囊压力值,护士长认识正确率只有16.7%;85%的护士长选用普通一次性吸痰管;75%的护士长用加热型湿化器;90%的护士长能够及时清除冷凝水;70%的护士长按污物处理冷凝水;80%的护士长要求护士戴上手套处理冷凝水;80%的护士长要求护士在无禁忌症时床头抬高30°~45°。结论:呼吸机相关性肺炎相关因素管理存在缺陷,护士长需加强学习和培训相关知识,合理管理,以降低呼吸机相关性肺炎的发生。 Objective:To understand management status about Ventilator-associated pneumonia risk factors,in 3 A-level hospitals of Urumqi Region,promoting management standardization,rationalization.Methods: The self-designed questionnaire to heads nurse of ICU,in 3 A-level hospitals of Urumqi Region,on the artificial airway management,condensation water management,and regular position management for investigation.Results:The reasonable of aerocyst pressure,heads nurse konowing on the proper rate is only 16.7%;85% of the heads using open suctioning;75% using heated humidifir;90% to remove condensation water in time,70% handling the condensed water by sewerage;80% requiring nurses to wear gloves when handling condensation water;80% using the semi-recumbent position(30°-45°),if on contraindications.Conclusion: The management shortcomings in the management of ventilator-associated pneumonia risk factors,heads nurse need to enhance the learning and training of relevant knowledge,rational management,in order to reduce the occurring of ventilator-associated pneumonia.
出处 《护理实践与研究》 2011年第12期132-134,共3页 Nursing Practice and Research
关键词 机械通气 呼吸机相关性肺炎 相关因素 管理 调查 Mechanical ventilation Ventilator-associated pneumonia Risk factors Management Investigation
  • 相关文献

参考文献18

  • 1Bauer TT,Ferrer R,Angrill J,et al.Ventilator-assoeiated Pneumonia:ineidenee risk factors and minerobiology[J].Semin ResPir Infeet,2000,15(4):272-279.
  • 2彭鎏,艾宇航.重症监护室患者人工气道相关肺炎调查分析[J].中国感染控制杂志,2005,4(3):223-226. 被引量:29
  • 3王继芳.呼吸机相关性肺炎的预防和护理进展[J].当代护士(中旬刊),2008,15(8):19-21. 被引量:5
  • 4Lorente L,Blot S,Rello J.Evidence on measures for the prevention of ventilator-associated pneumonia[J].Eur Respir J,2007,30(3):1193-1207.
  • 5机械通气临床应用指南(2006)[J].中国危重病急救医学,2007,19(2):65-72. 被引量:812
  • 6Rello J,Sonora R,Jubert P,et al.Pneumonia in intubated patients:role of respiratory airway care[J].Am J Respir Crit Care Med,1996,154(1):111-115.
  • 7Zeitoun SS,de Barros AL,Diccini S.A prospective,randomized study of ventilator-associated pneumonia in patients using a closed vs.open suction system[J].J Clin Nurs 2003,12(4):484-489.
  • 8Lorente L,Lecuona M,Garcia C,et al.Ventilator-associated pneumonia using a closed versus an open tracheal suction system[J].Crit Care Med,2005,33(1):115-119.
  • 9Lorente L,Lecuona M,Jimenez A,et al.Tracheal suction by closed system without daily change versus open system[J].Intensive Care Med,2006,32:538-544.
  • 10Cereda M,Villa F,Colombo E,et al.Closed system endotracheal suct ioning maintains lung volume during volume-controlled mchanical ve ntilation[J].Intensive Care Med,2001,27(4):648-654.

二级参考文献84

共引文献949

同被引文献75

引证文献6

二级引证文献76

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部