期刊文献+

实时心肌造影评价急性心肌梗死患者应用冠状动脉远端保护装置后心肌灌注的初步探讨

Primary Evaluation of Myocardial Perfusion in Patients with Acute Myocardial Infarction Using Distal Occlusion Balloon Protection Device by Real-time Myocardial Contrast Echocardiography
下载PDF
导出
摘要 目的:对急性心梗应用远端保护装置术后患者进行实时心肌造影检查,初步探讨患者术后心肌血流灌注恢复情况。材料与方法:急性心肌梗死入院并行急诊介入治疗联合应用冠脉远端保护装置术后患者3例应用SonoVue造影剂进行经静脉实时心肌造影检查。结果:患者均无任何不适。梗死相关节段室壁的功能和心肌灌注均得到了不同程度的恢复。结论:联合使用远端保护装置,可有效改善心肌灌注。 Purpose:To primarily evaluate the myocardial perfusion in patients with acute myocardial infarction using distal occlusion balloon protection devices by real-time myocardial contrast echocardiography(MCE).Materials and Methods:Three patients who had received percutaneous coronary intervention with distal protection devices before ten months were examined by real-time MCE.Results:The patients did not have any side effects.The perfusion of segments supplied by stenotic artery were improved.Conclusion:Myocardial perfusion can be improved using distal protection devices.
出处 《现代医用影像学》 2011年第1期12-13,23,共3页 Modern Medical Imageology
基金 陕西省科学技术研究发展计划(编号:2008K13-02) 西安医学院科研基金青年项目(编号:2006QN1)基金资助
关键词 实时心肌造影 心肌梗死 冠状动脉远端保护装置 Myocardial contrast echocardiography Myocardial infarction Distal occlusion balloon protection device
  • 相关文献

参考文献3

二级参考文献23

  • 1庄磊,王新房,谢明星,王瑶,费洪文,杨颖,黄润青,王静,卢晓芳,杨亚莉.定量组织速度成像技术评价PTCA支架置入后心肌功能改变的研究[J].中国医学影像技术,2004,20(7):1054-1056. 被引量:3
  • 2谢明星,王新房,黄润青,王静,王良玉,费洪文,杨颖陈立新,庄磊,陈欧迪,卢晓芳,杨亚利.实时三维超声心动图评价左室重构心功能的初步探讨[J].中国医学影像技术,2003,19(5):542-544. 被引量:20
  • 3黎鹏,邓又斌,杨好意,王红英,魏翔,张清阳,毕小军,申屠伟慧,黎春蕾,白姣.实时心肌超声造影评价冠状动脉搭桥术前后心肌灌注[J].中华超声影像学杂志,2007,16(4):294-297. 被引量:10
  • 4陈立军,李守平,张技革,杨浣宜,刘汉英,吴清玉.两维超声心动图评价冠心病心肌梗塞患者左室形态及其与心脏功能关系[J].中华超声影像学杂志,1997,6(3):152-155. 被引量:5
  • 5Imad S, Gabriele F, Giuseppe MC, et al. Time course and determinants of left ventricular function recovery after primary angioplasty in patients with acute myocardial infarction[J]. J Am Coll Cardiol, 2001,38(2) :464-471.
  • 6Topol EJ, Yadav JS. Recognition of the importance of embolization in atherosclerotic vascular disease[J]. Circulation, 2000, 101(5) :570-580.
  • 7Resnic FS, Wainstein M, Lee MK, et al. No-reflow is an independent predictor of death and myocardial infarction after percutaneous coronary intervention [J]. Am Heart J, 2003, 145 (1): 42-46.
  • 8Li SLL, Lam CW, So YC, et al. The use of a distal occlusion balloon protection device in acute coronary syndrome[J]. Int J Cardiol, 2003,92(2-3): 281-284.
  • 9Huang Z, Katoh O, Nakamura S, et al. Evaluation of the percusurge guardwire plus temporary occlusion and aspiration system during primary angioplasty in acute myocardial infarction [J].Catheter Cardiovasc Interv, 2003,60 (4): 443-451.
  • 10Boa J J, Patton JA, Poldermans D. 18 Fluorodeoxyflucose imaging with positron emission tomography and single photon emission computed tomography: cardiac applications. Semin Nucl Med, 2000,30(4) :281-298.

共引文献8