简要概述了某600MW超临界直流炉机组的特点,设计并实现了其RB控制逻辑。测试结果和机组运行实践验证了所设计的RB控制逻辑的正确性和有效性,该机组RB控制逻辑的设计与实现,可为同类型机组的RB控制逻辑提供重要的参考和有益的借鉴。
The feature of some 600MW supercritical once-through unit was introduced,and the design and implementation of Runback(RB) control strategy for the unit was proposed.The effectiveness and reliability of the RB control strategy were validated by the successful test and operation of the unit.The successful design and implementation of the RB control strategy for the unit can provide valuable reference and meaningful values for the kind of units with the same type.
出处
《仪器仪表用户》
2011年第3期81-83,共3页
Instrumentation
关键词
超临界
直流炉
负荷返回
设计
实现
supercritical
once-through
runback
design
implementation