摘要 目的 观察准分子激光原位角膜磨镶术(excimerlaserin situ keratomileusis,LASIK) 治疗中高度远视的安全性及有效性。方法 对9 例(17 只眼) 高度远视患者行LASIK。术前远视度数为+5-50 ~+ 9-00 D,平均为(+ 7-18±1-00) D。术后随访观察12 个月以上。结果 术中无严重并发症,术后最佳矫正视力与术前相比,未见视力下降超过1 行以上者。术后3 个月时,屈光度基本稳定;术后12 个月时,平均远视度数为( +1-77±1-56)D,未见屈光度在0 以下者,屈光度在0~+ 1-00 D者占53% (9/17);平均裸眼远视力为0-60±0-17,其中≥0-5 者15 只眼(88% );平均裸眼近视力为0-98±0-24 ,其中≥0-5 者17 只眼(100 %) 、≥1-0 者13 只眼(77% )。结论 LASIK 对于中高度远视治疗具有良好的安全性及有效性,对于治疗参数尚需作进一步调整。 Objective To evaluate safety and efficacy of excimer laser in situ keratomileusis (LASIK) for high and moderate hyperopia Methods LASIK was performed on 17 eyes of 9 patients using the SCHWIND KERATOM F excimer laser The range of preoperative spherical equivalent was +5 50~+9 00 D, and its mean value, (+7 18±1 00) D All the cases were followed up for 12 months or longer Results There was no serious complication during the operation No eye lost more than 1 line of the best corrected visual acuity after surgery At 12 months, the mean postoperative spherical equivalent was (+1 77±1 56)D 52 9% of eyes reached 0 to +1 00 diopter 88 2% of eyes achieved an uncorrected far vision of ≥0 5 100 0% and 76 5% eyes got uncorrected near visual acuities of ≥0 5 and ≥1 0 respectively Conclusion It is demonstrated the LASIK is a safe and effective technique for the treatment of high and moderate hyperopia Further algorithm calibration must be made to avoid undercorrection
出处 《中华眼科杂志》 CAS CSCD 北大核心 1999年第6期456-458,共3页 Chinese Journal of Ophthalmology
关键词 远视 准分子激光 原位角膜磨镶术 Hyperopia Excimer laser in situ keratomileusis
  • 相关文献

参考文献4

二级参考文献2

共引文献40

同被引文献50

引证文献13

二级引证文献49

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部