摘要 The photoplethysmogram(PPG) of a pulse wave,similar in appearance to the arterial blood pressure(ABP) waveform,contains rich information about the cardiovascular system.The decay time constant RC,equal to the product of peripheral resistance R and total arterial compliance C,is a meaningful cardiovascular model parameter in vascular assessment.Using or ameliorating the existing ABP methods does not achieve a satisfactory estimation of RC from the PPG volume pulse(VRC).Thus,a novel non-iterative shape method(NSM) of evaluating VRC is introduced in this paper.The mathematic expression between a novel,readily available morphological parameter called the area difference ratio(ADR) and VRC was established.As it was difficult to calculate VRC from the complicated expression analytically,we recommend estimating it using a piecewise linear interpolation criterion.Also,since the effect of the PPG magnitude is eliminated in the calculation of ADR,precaliberation or normalization is dispensable in the NSM.Results of human experiments indicated that the NSM was computationally efficient,and the simulation experiments confirmed that the NSM was theoretically available for ABP. The photoplethysmogram (PPG) of a pulse wave, similar in appearance to the arterial blood pressure (ABP) wave- form, contains rich information about the cardiovascular system. The decay time constant RC, equal to the product of peripheral resistance R and total arterial compliance C, is a meaningful cardiovascular model parameter in vascular assessment. Using or ameliorating the existing ABP methods does not achieve a satisfactory estimation of RC from the PPG volume pulse (VRC). Thus, a novel non-iterative shape method (NSM) of evaluating VRC is introduced in this paper. The mathematic expression between a novel, readily available morphological parameter called the area difference ratio (ADR) and VRC was established. As it was difficult to calculate VRC from the complicated expression analytically, we recommend estimating it using a piecewise linear interpolation criterion. Also, since the effect of the PPG magnitude is eliminated in the calculation of ADR, precaliberation or normalization is dispensable in the NSM. Results of human experiments indicated that the NSM was computationally efficient, and the simulation experiments confirmed that the NSM was theoretically available for ABP.
出处 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2011年第6期438-445,共8页 浙江大学学报(英文版)A辑(应用物理与工程)
基金 Project (No.81070885) supported by the National Natural Science Foundation of China
关键词 Photoplethysmogram(PPG) Decay time constant Non-iterative shape method(NSM) Area difference ratio(ADR) Photoplethysmogram (PPG), Decay time constant, Non-iterative shape method (NSM), Area difference ratio (ADR)
  • 相关文献

参考文献33

  • 1Ahonen, J., Jokela, R., Uutela, K., Huiku, M., 2007. Surgical stress index reflects surgical stress in gynaecological laparoscopic day-case surgery. British Journal of Anaesthesia, 98(4):456-461. [doi:10.1093/bja/aem035].
  • 2Alastruey, J., Parker, K.H., Peiro, J., Sherwin, S.J., 2009. Analysing the pattern of pulse waves in arterial networks: a time-domain study. Journal of Engineering Mathematics, 64(4):331-351. [doi:10.1007/s10665-009-9275-1].
  • 3Allen, J., 2007. Photoplethysmography and its application in clinical physiological measurement. Physiological Measurement, 28(3):R1-R39. [doi:10.108810967-3334/28/3/R01].
  • 4Bhattacharya, J., Kanjilal, RP., Muralidhar, V., 2001. Analysis and characterization of photo-plethysmographic signal. IEEE Transactions on Biomedical Engineering, 48(1): 5-11. [doi: 10.1109/10.900243].
  • 5Eyal, S., Oz, O., Eliash, S., Wasserman, G., Akselrod, S., 1997. The diastolic decay constant in spontaneously hypertensive rats versus WKY rats as an indicator for vasomotor control. Journal of the Autonomic Nervous System, 64(1):24-32. [doi:10.1016/s0165-1838(97)00012-X].
  • 6Fogliardi, R., Burattini, R., Shroff, S.G., Campbell, K.B., 1996. Fit to diastolic arterial pressure by third-order lumped model yields unreliable estimates of arterial compliance. Medical Engineering & Physics, 18(3):225-233. [doi:10. 1016/1350-4533(95)00042-9].
  • 7Gnudi, G., 1998. New closed-form expressions for the estimation of arterial Windkessel compliance. Computers in Biology and Medicine, 28(3):207-223. [doi:10.1016/ 90010-4825(98)00008-0].
  • 8Haffty, B.G., O'Hare, N.E., Singh, J.B., Spodick, D.H., 1983. Noninvasive tracking of peripheral resistance by ear densitography. Chest, 83 (5):771-775. [doi:10.1378/chest. 83.5.771].
  • 9Hashimoto, J., Chonan, K., Aoki, Y., Nishimura, T., Ohkubo, T., Hozawa, A., Suzuki, M., Matsubara, M., Michimata, M., Araki, T., et al., 2002. Pulse wave velocity and the second derivative of the finger photoplethysmogram in treated hypertensive patients: their relationship and associating factors. Journal of Hypertension, 20(12): 2415-2422.
  • 10Huiku, M., Uutela, K., van Gils, M., Korhonen, I., Kymalainen, M., Merilainen, P., Paloheimo, M., Rantanen, M., Takala, P., Viertio-Oja, H., et al., 2007. Assessment of surgical stress during general anaesthesia. British Journal of Anaesthesia, 98(4):447-455. [doi:10. 1093/bja/aem004].