期刊文献+

气液双热源耦合换热器性能研究 被引量:5

Performance of an air-liquid dual heat source coupled heat exchanger
下载PDF
导出
摘要 设计了一种由管翅式换热器和套管式换热器耦合而成的气液双源耦合式换热器,该换热器可以实现一种介质同时与气态热源和液态热源进行同步耦合换热。对该换热器进行了详细的介绍,并对其耦合换热特性及该换热器在耦合热源热泵空调中应用时的制热工况进行了的性能测试。研究结果证明,使用该气液双热源耦合式换热器的耦合热源热泵空调系统,气液双热源模式与单空气热源模式相比,制热量和COP均有明显提高,低温时性能提高更为显著。当空气温度为-15℃时,制热量及系统COP提高50%以上。 A dual heat source coupled heat exchanger was designed, which was integrated based on the fin heat exchanger and the double pipe heat exchanger. The synchronized compound heat exchanger could do heat exchange with gas and liquid heat source at the same time. In this paper, the coupled heat exchanger was described in detail, and the compound heat exchange per- formance and heating performance of coupled heat pump with the coupled heat exchanger were tested. The results proved, com- pared the air - liquid dual heat source with single air heat source, the heating capacity and COP of the gas - liquid,mode were all raised evidently, especially in low air temperature. When the air temperature was - 15℃, the heat pump heating capacity and COP of the air - liquid mode raised more than 50% than single air source mode.
出处 《低温与超导》 CAS CSCD 北大核心 2011年第6期44-47,共4页 Cryogenics and Superconductivity
基金 河南省重点科技攻关项目(072102240013) 河南省基础与前沿技术研究计划项目(082300460150)
关键词 双热源 换热器 热泵 热特性 Two heat source, Heat exchanger, Heat pump, Thermal performance
  • 相关文献

参考文献5

  • 1Kuppan T. Heat Exchanger Design Handbook [ M ]. Boca Raton, USA : CRC Press, 2000.
  • 2清华大学建筑节能研究中心.中国建筑节能年度发展研究报告2007[M].中国建筑工业出版社,2007.
  • 3阳季春,季杰,裴刚,蒋爱国,何伟.间接膨胀式太阳能多功能热泵供热实验[J].中国科学技术大学学报,2007,37(1):53-60. 被引量:25
  • 4Wang C C. Effects of Waffle Height on The Air - Side Performance of Wavy Fin - and - Tube Heat Exchanger [J], Heat Transfer, 1999,20(3) :45 -56.
  • 5R K Shah Dus an P Sekulic. Fundamentals of Heat Exchanger Design[ M]. Hoboken N J, USA:John Wiley & Sons, Inc., 2003.

二级参考文献14

  • 1季杰,裴刚,何伟,董军.空调-热水器一体机单独制热水模式的性能模拟和实验分析[J].暖通空调,2004,34(12):96-98. 被引量:17
  • 2季杰,蒋斌,陆剑平,易桦,何伟,裴刚.新型PV-Trombe墙的实验[J].中国科学技术大学学报,2006,36(4):349-354. 被引量:17
  • 3Freeman T L, Mitchell J W, Audit T E. Performance of combined solar-heat pump systems[J]. Solar Energy, 1979, 22(2):125-135.
  • 4Sushil K Chaturvedi, James Y Shen.Thermal performance of a direct expansion solar-assisted heat pump[J]. Solar Energy, 1984,33 (2):155-162.
  • 5Pietsch J A. Optimization of loop temperatures in water loop heat pump systems[C]// ASHRAE Transactions, 1991,97(part 2) :713-726.
  • 6Morrison G L. Simulation of packaged solar heat-pump water heaters[J]. Solar Energy, 1994,53(3):249-257.
  • 7Chaturvedi S K, Chen D T, Kheireddine A. Thermal performance of a variable capacity direct expansion solar-assisted heat pump[J]. Energy Conversion and Management, 1998, 39(3-4):181-191.
  • 8Kaygusuz K, Ayhan T. Experimental and theoretical investigation of combined solar heat pump system for residential heating [ J ].Energy Conversion Management, 1999, 40(13):1 377-1 396.
  • 9Chyng J P, Lee C P, Huang B J. Performance analysis of a solar-assisted heat pump water heater[J]. Solar Energy, 2003, 74(1).33-44.
  • 10Kuang Y H, Sumathy K, Wang R Z. Study on a direct-expansion solar-assisted heat pump water heating system[J]. International Journal of Energy Research,2003, 27:531-548.