摘要
龙滩水电站地下厂房结构复杂,且地处南方特有的不利气候环境。为保证电站通风空调设备能可靠稳定、合理分配运行,电站厂房采用了自动化通风空调控制系统。文中概要介绍了该系统的结构和主要设备及功能,并简要叙述了该系统的设计思想。
The structure of the underground power-house for Longtan Hydropower Station is complicated, and furthermore, is located in an unfavourable climate circumstance that is particular in the Southern China. A ventilating and air conditioning automatic control system is adopted for the powerhouse of the palnt, so as to ensure the reliable and reasonable operation and distribution of the ventilating and air conditioning equipment therein. The structure, main equipment and function of the system is briefly introduced herein, moreover, the design concept of the system is generally described as well.
出处
《水利水电技术》
CSCD
北大核心
2011年第6期48-51,共4页
Water Resources and Hydropower Engineering
关键词
龙滩水电站
通风空调系统
自动化控制
运行管理
Longtan Hydropower Station
ventilating and aie conditioning system
automatic control
operation and management