实验室无源效率刻度技术的准确性检验 被引量:13

Calibration Check for Efficiency Scale of Sourceless Detection in Laboratory
下载PDF
导出
摘要 为检验无源效率刻度技术的准确性,本文用9个可溯源的典型放射性样品进行测试,并用LabSOCS计算结果。结果表明,点源在低能区(<150KeV)偏差为9.2%,中高能区5.9%以内。对于单一核素体源,偏差在5%以内,而复合核素体源偏差在12%以内,无源效率刻度技术是一种准确、可靠的刻度技术。 For calibration of efficiency scale in sourceless detection,nine typical radiation samples that are traceable were checked.The results were obtained by using Laboratory Sourceless Calibration Software(LabSOCS) to calculate.It shows that the deviations of point source samples were 9.2% and 5.9% at low-energy area(150KeV)and high-energy area respectively.For cylinder samples with single-nuclide and with multi-nuclide the deviations were less than 5% and 12% respectively.The technology of efficiency scale of sourceless detection is precise and reliable.
出处 《四川环境》 2011年第3期5-9,共5页 Sichuan Environment
关键词 HPGe谱仪 实验室无源效率刻度 准确性 检验 HPGe detector LabSOCS accuracy check
  • 相关文献

参考文献8

二级参考文献41

  • 1向长兴.一组实用γ谱分析效率刻度曲线[J].核电子学与探测技术,1994,14(6):363-366. 被引量:9
  • 2GB/T 16140-1995,水中放射性核素的γ能谱分析方法[S].
  • 3郝润龙,谭金波.JJG578-94锗γ谱仪体源活度测量装置检定规程[S].
  • 4何宗慧.近距离测量时Ge(Li)探测器的峰效率刻度和符合相加修正[J].辐射防护,1986,6(6):431-431.
  • 5Debertin K. And Schotzig U. Coincidence summing corrections in Ge(Li)-spectrometry at low source to detector distances[J]. Nuclear Instruments and Methods. 1979 158,471.
  • 6Ashrafi S, Likar A, Vidmar T. Precise modeling of a coaxial HPGe detector[J]. Nuclear Instruments and Methods, 1999,438,421.
  • 7Gerhard Haase, David Tait, Arnold Wiechen. Application of a new Monte Carlo method for determination of summation and self -attenuation corrections in gamma spectrometry [J]. Nuclear Instruments and Methods, 1993,336, 206.
  • 8Korun M, Likar A, Vidmar T. Monte-Carlo calculation of the spatial dependence of the coaxial HPG e detector efficiency for point sources[J]. Nuclear Instruments and Methods,1997,390,203.
  • 9Marc Decombaz,Jean Jacques Gostely, Jean Pascal Laedermann.Coincedence summing corrections for extended sources in gamma -ray spectrometry using Monte Carlo simulation [J]. Nuclear Instruments and Methods,1992, 312,152.
  • 10Arnold D, Wershofen H. Specific calibration problems for gammaspectrometric measurements of low-level radioactivity in environmental samples, Methods and applications of low- level radioavtivity measuements[J]. Proceeding, 1997,170,1139-142.