钢渣中游离氧化镁含量的测定 被引量:10

Determination of Free Magnesium Oxide in the Slag
下载PDF
导出
摘要 研究和提出了以硝酸铵-乙醇作为提取剂提取活性氧化镁(即游离氧化镁)的分析方法。通过正交实验,选取了最佳的提取条件。样品平行测定的相对标准偏差在0.51%-2.13%之间,回收率实验结果为98.2%-99.0%,表明该实验的精密度和准确度均较好。采用硝酸铵-乙醇作为提取剂提取游离氧化镁的分析方法,实现了钢渣中游离氧化镁的快速、准确测定,为钢渣的回收再利用提供了依据。 A new analytical method was investigated and proposed for determination of active magnesium oxide(free magnesium oxide) in the slag using ammonium nitrate-ethanol as the extraction reagent.Through the orthogonal design experiments,the optimized working conditions were found.The parallel testing gave the RSDs of 0.51%~2.13%,the recoveries of 98.2%~99.0%,indicating good precision and accuracy of the method.The method provides a technical solution for the slag recovery by allowing rapid and accurate determination of free magnesium oxide in the slag.
出处 《中国无机分析化学》 CAS 2011年第2期54-57,共4页 Chinese Journal of Inorganic Analytical Chemistry
关键词 钢渣 游离氧化镁(f-MgO) 硝酸铵 slag free magnesium oxide(f-MgO) ammonium nitrate
  • 相关文献