期刊文献+

植入心血管电子器械后感染的相关危险因素 被引量:4

下载PDF
导出
摘要 随着适应证和适用人群的不断拓宽,心脏植入式电子器械的使用数量在逐年增加,患者术后感染的发生率也显著增加。植入超过2根电极、器械类型、更换脉冲发生器、术前使用临时起搏器、术前24 h发热、术中经验、患者年龄、长期使用抗凝剂及类固醇激素、伴随疾病都可以增加或影响感染发生率,术前使用抗生素可以降低感染的发生率。
出处 《中国心脏起搏与心电生理杂志》 北大核心 2011年第3期263-265,共3页 Chinese Journal of Cardiac Pacing and Electrophysiology
  • 相关文献

参考文献26

  • 1Voigt A, Shalaby A, Saba S. Continued rise in rates of cardiovascular implantable electronic device infections in the United States: temporal trends and causative insights[ J]. Pacing Clin Electrophysiol,2010,33:414.
  • 2Sohail MR, Uslan DZ, Khan AH, ct al. Risk factor analysis of permanent pacemaker infection [ J ]. Clin Infect Dis, 2007,45 : 166.
  • 3Chauhan A, Grace AA, Newell SA, et al. Early complications after dual chamber versus single chamber pacemaker implantation [J]. Pacing Clin Electrophysiol,1994,17:2 012.
  • 4Uslan DZ, Sohail MR, St Sauver JL, et al. Permanent pacemaker and implantable cardioverter defibrillator infection: a population- based study[J]. Arch Intern Med, 2007,167:669.
  • 5Nery PB, Fernandes R, Nair GM, et al. Device-related infection among patients with pacemakers and implantable defibrillators: incidence, risk factors, and consequences [ J]. J Cardiovasc Electrophysiol,2010,21:786.
  • 6Johansen JB N J, Arnsbo P, Moller M, et al. Higher incidence of pacemaker infection after replacement than after first implantation: experiences from 36,076 consecutive patients[ J ]. Heart Rhythm, 2006 : S102.
  • 7Lekkerkerker JC, van Nieuwkoop C, Trines SA, et al. Risk factors and time delay associated with cardiac device infections: Leiden device registry[ J]. Heart,2009,95:715.
  • 8Baman TS, Gupta SK, Valle JA, et al. Risk factors for mortality in patients with cardiac device-related infection [ J ]. Circ Arrhythm Electrophysiol, 2009,2 : 129.
  • 9Howarth DM, Curteis PG, Gibson S. Infected cardiac pacemaker wires demonstrated by Tc-99m labeled white blood cell scintigraphy [J]. ClinNucl Med, 1998,23:74.
  • 10Conklin EF, Giannelli S, Nealon TF. Four hundred consecutive patients with permanent transvenous pacemakesr[J].J Thorac Cardiovasc Surg, 1975,69 : 1.

同被引文献36

  • 1王现青,张嘉莹,张静,高传玉.心脏临时起搏在老年患者围手术期中的应用[J].实用诊断与治疗杂志,2004,18(6):537-538. 被引量:8
  • 2陶以嘉,金伟东,李春庆.床旁应用带气囊漂浮起搏导管抢救心脏急症的临床研究[J].中国急救医学,2005,25(10):768-769. 被引量:17
  • 3中华人民共和国卫生部.医院空气净化管理规范[S].北京:中国标准出版社,2012:1-7.
  • 4Laczika K,Thalhammer F, Locker G* et al. Safe and efficientemergency transvenous ventricular pacing via the rightsupraclavicular route[J], Anesth Analg,2000,90(4) :784-789.
  • 5Ferguson JD, Banning AP, Bashir Y. Randomised trial oftemporary cardiac pacing with semirigid and balloon-flotationelectrode catheters[J]. Lancet, 1997,349(9069) :1883.
  • 6Klug D, Balde M, Pavin D, et al. Risk factors related to infec- tions of implanted pacemakers and cardioverter-defibrillators results of a large prospective study[-J]. Circulation, 2007, 116 (12) : 1349-1355.
  • 7Eldstein AE, DiMarco JP, Ellenbogen KA, et al. ACC/AHA/ HRS 2008 Guidelines for Deviee-Based Therapy of Cardiac Rhythm Abnormalities[J]. Circulation, 2008,117 : 350- 408.
  • 8Zipes DP, Carom AJ, Borggrefe M, et al. ACC/AHA/ESC 2006 Guidelines for Management of Patient With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death[J]. Circulation. 2006. 114::185 -484.
  • 9Uslan DZ, Sohail MR, Sauver J I.S, et al. Permanent pacemaker and implantable cardioverter defibrillator infection., a popula- tion- based study[J]. Archives of Internal Medicine, 2007, 167 (7):669-675.
  • 10谢景超.糖尿病控制与并发感染的相关性研究[J].中国感染控制杂志,2008,7(1):1-4. 被引量:19