期刊文献+

整合并行采集技术在腹部磁共振检查中的应用价值 被引量:3

Application of integrated parallel acquisition technique in abdominal MRI
下载PDF
导出
摘要 目的探讨整合并行采集技术在腹部磁共振检查中的应用价值。方法选择需行腹部磁共振检查的50例患者,先行磁共振T1加权、T2加权加三维抑脂扰相梯度回波序列(3D-FS-SPGR)扫描(T1WI+3D-FS、T2WI+3D-FS)(A方法),在此基础上进行整合并行采集序列扫描(B方法)。比较两组图像的差异。结果两种方法所得的腹部MRI图像均能达到诊断标准,但整合并行采集序列的图像质量、降低呼吸运动伪影情况均优于T1WI+3D-FS、T2WI+3D-FS,且扫描时间明显缩短(P<0.05)。结论整合并行采集序列扫描技术可提高信号的采集速度,使图像更清晰,并可有效减少呼吸运动伪影对图像的影响,对腹部磁共振检查后的诊断有重要价值。 Objective To discuss application of integrated parallel acquisition technique(IPAT) in abdominal MRI.Methods Fifty cases of acquiring abdominal MRI were selected, undergoing T1 weighted, T2 weighted and fat-suppressed spoiled gradient-echo (3D-FS-SPGR ) sequence scanning (T1WI 3D-FS,T2WI 3D-FS)(method A);based on method A ,IPAT was used(method B), and then the image difference in the two methods was analyzed.Results The quality of both kinds of pictures of abdominal MRI could achieve diagnosis, but with a short scanning time, method B obtained the good image quality and reducing respiratory motion artifacts compared with method A(P0.05).Conclusion IPAT scanning technology can increase signaling speed and image quality, and reduce respiratory motion artifact in abdominal MRI and play an important role in making an accurate diagnosis for disease.
出处 《白求恩军医学院学报》 2011年第3期172-173,共2页 Journal of Bethune Military Medical College
关键词 三维抑脂扰相梯度回波序列 T1加权 T2加权 整合并行采集技术 Fat-suppressed spoiled gradient-echo T1 weighted T2 weighted Integrated parallel acquisition technique
  • 相关文献

参考文献4

  • 1赵海涛 耿江红 陆军 等.磁共振iPAT并行采集技术及其应用.中国卫生设备,2008,29(10):338-339.
  • 2史浩.8通道头部线圈和iPAT技术在MRI颅脑检查中的应用[J].医学影像学杂志,2006,16(4):329-332. 被引量:11
  • 3Pruessmann KP,Weiger M,Scheidegger MB,et al.SENSE:sensitivity encoding for fast MRI[J].Magn Reson Med,1999,42(5):952-962.
  • 4Heidemann RM,Ozsarlak O,Parizel PM,et al.A brief review of parallel magnetic resonance imaging[J].Eur Radio1,2003,13(10):2323-2337.

二级参考文献6

  • 1Zwart JA, Ledden PJ, Kellman P, et al. Design of a iPAT-optimizedhigh-sensitivity MRI receive coil for brain imaging[J]. Magn Reson Med, 2002,47:1218 - 1227.
  • 2Porter JR, Wright SM, Reykowski A. A 16-element phased-array head coil[J]. Magn Reson Med, 1998,40:272-279.
  • 3Weiger M, Pruessmann KP, Kassner A, et al. Contrast-enhanced 3D MRA using iPAT[J]. JMRI,2000,12:671 - 677.
  • 4Dydak U, Weiger M, Pruessmann KP, et al. Sensitivity encoded multi-echo spectroscopic imaging[J]. In: Proc ISMRM, 8th Annual Meeting, Denver, 2000.368.
  • 5Golay X, Pruessmann KP, Weiger M, et al. PRESTO-iPAT: an ultrafast whole brain fMRI technique[J]. Magn Resort Med,2000,43:779- 786.
  • 6Pruessmann KP, Weiger M, Boesiger P. Sensitivity encoded cardiac MRI[J]. J Cardiov Magn Reson,2001,3:1-9.

共引文献11

同被引文献9

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部