期刊文献+

天津陈塘热电厂烟气排放连续监测系统的设计 被引量:1

Design of Continuous Emission Monitoring System of Chentang Thermal Power Plant in Tianjin
下载PDF
导出
摘要 介绍了天津陈塘热电有限公司3期工程2×300MW机组烟气排放连续监测系统(CEMS,Continuous Emis-sion Monitoring System)的设计选型,比较了CEMS的几种主要技术及其特点。根据对比和咨询当地环保管理部门,陈塘热电选用直接抽取法。该套设备安装调试后,能够实现准确测量,为陈塘热电创造了一定的经济效益。实践证明,陈塘热电所选用的CEMS系统是可靠准确的。 The design selection of Phase 3 2×300 MW units continuous emission monitoring system(CEMS) of Chentang Thermal Power Co.,Ltd.in Tianjin was introduced,several major technology and characteristics of the CEMS were compared.Based on compared and consulted local environmental management,direct thermal extraction method was used in Chentang Thermal Power Plant.The equipment installation can achieve accurate measurements,and created certain economic benefits for Chentang Thermal Power Plant.The practical results show that CEMS systems of Chentang Thermal Power Plant are reliable and accurate.
出处 《能源研究与管理》 2011年第2期67-70,共4页 Energy Research and Management
关键词 火电厂 节能减排 烟气连续排放监测系统(CEMS) thermal power plant energy saving continuous emission monitoring system(CEMS)
  • 相关文献