期刊文献+

ALS 2.3综合录井仪隔离器设置方法 被引量:3

The setting method for the isolator of ALS 2.3 Comprehensive Mud Logging Unit
下载PDF
导出
摘要 ALS 2.3综合录井仪接口部分所用隔离器在实际应用中有时需要重新进行地址设置和参数设置,为此从仪器接口单元功能结构入手阐述了设置方法。以泵冲传感器的隔离器为例,系统地介绍了PactWare软件设置隔离器参数的操作步骤,为录井过程中隔离器出现故障时能及时处理以保证录井生产的正常进行,提供了一个可行的途径,该方法同时也节约了成本,缩短了维修时间。 The isolator used in the interface of ALS 2.3 Comprehensive Mud Logging Unit is needed to reset the address and parameters during the application,so the setting methods are described from the functional structure of the instrument interface.Taking the isolator in the pump stroke sensor as the example,the paper systematically introduced the operating procedures of the parameter setting by PactWare software,which provided the flexible guiding idea for the timely treatment when the isolator failed during the mud logging process to ensure normal logging production.Meanwhile,using this method can also save the cost and shorten the repairing time.
作者 杨君 吉善杰
出处 《录井工程》 2011年第2期27-29,75,共3页 Mud Logging Engineering
关键词 综合录井仪 隔离器 485数据采集模块 以太数据网关 PactWare软件 comprehensive mud logging unit,isolator,485 data acquisition module,Ethernet data gateway,PactWare software