特高压天然气压缩因子的实验测定 被引量:6

Measurement of the Compressibility Factor of Natural Gases at Super High Pressure
下载PDF
导出
摘要 针对海上和新疆油气藏压力高的特点,设计制造了一套特高压PVT实验装置,其最高工作压力为130MPa,最高工作温度为200℃。测定了3个气样,50~140℃,20~100MPa范围内的PVTZ值,共取得346个数据点,其中对比压力只大于15的数据为178个。 An apparatus for super high pressure PVT measurement with maximum working temperature200℃ and maximum working pressure 130MPa has been established. The measurement with pure N2in the range of 20~150℃ and 20~100MPa gives an error less than 1% compared with the literaturedata. With this apparatus, the compressibility factors of 3 natural gas samples were measured in therange of 50~140℃ and 20~100MPa. The experiment data points amount to 346, and the reducedpressures of 178 points are above 15.
出处 《高校化学工程学报》 EI CAS CSCD 北大核心 1999年第5期393-397,共5页 Journal of Chemical Engineering of Chinese Universities
关键词 高压 压缩因子 测定 天然气 特高压 储藏量 high pressure compressibility factor measurement