期刊文献+

节流装置流量测量的分析 被引量:2

Analysis on Flow Measurement of Throttle Devices
下载PDF
导出
摘要 节流装置流量测量是目前工业生产中用来测量气体、液体和蒸汽流量常用的一种流量测量方式,选择合适的公称直径和径比才能保持流量测量的精度和节能效果,否则,流量测量的精度将受到影响,也不利于节能。通过对节流装置流量测量进行分析,分析影响节流装置流量测量精度的因素,分析表明采用不同径比和雷诺数范围时,其测量精度不同。通过提出采用一些选用原则,从而提高流量测量的测量精度,达到节能效果。 Throttle flow measurement is often used to measure gas, liquid and steam flow rate during industrial production, select the appropriate nominal diameter and the diameter ratio in order to maintain the accuracy of flow measurement and energy-saving effect, otherwise, the flow measurement accuracy will be affected, it is not beneficial for energy conservation. Through analyzing of throttle flow measurement, the factors which will affect the accuracy of flow measurement is also analyzed, analysis result show that different diameter ratio and Reynolds number will lead to different aecurancy. By recommending some selection principle, to improve the accuracy of flow measurement and save energy.
作者 彭年仔
出处 《石油化工自动化》 CAS 2011年第3期49-51,共3页 Automation in Petro-chemical Industry
关键词 流量测量 流出系数 雷诺数 径比 fluid flow measurement discharge coefficient Reynolds number diameter ratio
  • 相关文献

参考文献3

二级参考文献8

共引文献38

同被引文献18

  • 1胡明祥.对节流孔口流量特性的讨论[J].鄂州大学学报,2001,8(4):60-61. 被引量:7
  • 2刘跃.内锥流量计的探讨[J].自动化仪表,2004,25(3):38-42. 被引量:19
  • 3胡肖峰,谷汉斌,周华兴.平板门闸孔淹没出流流量系数推求[J].水科学与工程技术,2006(4):20-22. 被引量:6
  • 4ISO. ISO 5167-2:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full-part2 :orifice plates [ S ]. 2nd Edition. 2003.
  • 5Singh S N,Seshadri V,Singh R K,et al. Effect of upstream flow disturbances on the performance characteristics of a V-cone flowmeter [ J ]. Flow Measurement and Instrumentation,2006,17(5) :291-297.
  • 6Feng Dong, Hu Jun. Study of the gas-liquid two-phase flow measuring method based on the V-cone flowmeter [ C ]//The 5th International Symposium on Measurement Techniques for Multiphase Flows, Macao, China,2006:214 -220.
  • 7Lockhart R W,Martinelli R C. Proposed correlation of data for isothermal two-phase, two-component flow in pipe [ J ]. Chemical Engineering Progress, 1949,45 ( 1 ) :39 - 48.
  • 8Murdock J W. Two-phase flow through measurement with orifices [ J ]. Journal of Basic Engineering, 1962,84 (4) :419 - 433.
  • 9Chisholm D. Two-phase flow through sharp-edged orifices [ J ]. Joumal of Mechanical Engineering Science, 1977,19(3) :128 -130.
  • 10Lin Z H. Two-phase flow measurement with sharp-edged orifices [ J ]. International Journal of Multiphase Flow, 1982,8 (6) :683 - 693.