期刊文献+

不同负荷特性下单U型地埋管换热器换热性能模拟分析 被引量:3

Simulation and analysis of thermal performance of single U-tube ground heat exchanger under different load conditions
下载PDF
导出
摘要 文章对单U型地埋管换热器建立二维传热模型,并通过二维截面推移得到其三维模型。运用Ansys热分析软件,分析了某地区在不同空调负荷特性下的单U型地埋管换热器换热性能。模拟结果表明,单U型地埋管换热器在连续负荷作用下,每延米换热量从运行初期的约130 W下降到末期的34 W左右,在连续运行约200 h后基本保持不变;在间歇负荷作用下,每天运行末期的每延米换热量下降缓慢,在运行8 d后基本不变,保持在48 W左右,与连续负荷相比,换热器的热堆积小。 A two-dimensional heat transfer model of the single U-tube ground heat exchanger is established,and its three-dimensional model is achieved based on the two-dimensional section by neglecting the axial heat conduction effect.Through the thermal analysis by Ansys software,the simulation of the thermal performance of the single U-tube ground heat exchanger in a district under different air conditioning load conditions is carried out.The simulation results reveal that under continuous load,the quantity of heat exchange per meter drops from 130 W at the beginning of operation down to 34 W in the end,and keeps almost unchanged after 200 hours' continuous operation.While under intermittent load,the quantity of heat exchange per meter at the end of daily operation decreases slowly,and keeps at 48 W unchanged after 8 days' operation.Less thermal accumulation is gained under the second operation mode.
出处 《合肥工业大学学报(自然科学版)》 CAS CSCD 北大核心 2011年第6期873-876,共4页 Journal of Hefei University of Technology:Natural Science
关键词 单U型地埋管换热器 空调负荷特性 模拟 换热性能 single U-tube ground heat exchanger characteristic of air conditioning load simulation thermal performance
  • 相关文献

参考文献7

二级参考文献15

  • 1高祖锟.用于供暖的土壤-水热泵系统[J].暖通空调,1995,25(4):9-12. 被引量:21
  • 2刁乃仁,方肇洪.地埋管地源热泵技术[M].北京:高等教育出版社,2003:19-50.
  • 3Mei V C. Heat transfer of buried pipe for heat pump application [J]. Transaction of ASME, Journal of Solar Energy Engineering, 1991,133 :. 51-- 55.
  • 4章熙民,任泽霈.传热学[M].第4版.北京:中国建筑工业出版社,2005:15-18.
  • 5高祖锟,暖通空调,1993年,4期,9页
  • 6Lei T K,ASHRAE Trans,3635页
  • 7Mei V C,ASHRAE Trans A,92卷,30页
  • 8田胜元.实验设计与数据处理[M].北京:中国建筑工业出版社,2002..
  • 9Gu Y, O' Neal D L. Development of an equivalent diameter expression for vertical U-tube in GSHP. In:ASHRAE Trans. 1998, 104(2). 347- 355.
  • 10Kavanaugh S P, Rafferty K. Ground-Source Heat Pumps:Design of Geothermal Systems for Commercial and Institutional Building. Atlanta: ASHRAE Inc, 1997.