摘要 目的:评价3种不同根管预备系统对弯曲根管预备的效果,为其临床应用提供依据。方法:选择需要进行下颌磨牙根管治疗患者60例,共60颗下颌磨牙,随机分为手动不锈钢K锉组、Mtwo机用Ni-Ti器械组和Protaper机用Ni-Ti器械组,每组20颗牙,分别采用传统的手动不锈钢K锉、Mtwo机用Ni-Ti旋转系统和Protaper机用Ni-Ti旋转系统进行根管预备,对3种器械预备根管的时间和根管预备效果进行比较分析。结果:Mtwo和Protaper机用Ni-Ti器械组的并发症发生率明显低于手动不锈钢K锉组(P<0.01),根管预备平均操作时间明显少于手动不锈钢K锉组(P<0.01),而Mtwo与Protaper机用Ni-Ti器械组间比较差异无统计学意义(P>0.05)。3组间的根管充填效果比较差异无统计学意义(P>0.05)。结论:Mtwo和Protaper机用Ni-Ti旋转系统对根管的预备效果优于手动不锈钢K锉组。
出处 《吉林大学学报(医学版)》 CAS CSCD 北大核心 2011年第3期542-544,共3页 Journal of Jilin University:Medicine Edition
基金 国家自然科学基金资助课题(30830108C1708)
  • 相关文献

参考文献11

  • 1Foschi F, Nucci C, Montebugnoli L, et al, SEM evaluation of canal wall dentine following use of Mtwo and ProTaper NiTi rotary instruments[J]. Int EndodJ, 2004, 37(12): 832-839.
  • 2SchMer E, Erler M, Dammaschke T. Comparitive study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 1. Shaping ability in simulated curved canals[J]. IntEndodJ, 2006, 39(3): 196-202.
  • 3Schafer E, Erler M, Dammasehke T. Comparitive study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth[J]. Int Endod J, 2006, 39(3): 203-212.
  • 4Martin B, Zelada G, Varela P, et al. Factors influencing the fracture of nickel-titanium rotary instruments[J]. Int Endod J, 2003, 36(4): 262-266.
  • 5Buchanan LS. The standardized-taper root canal preparation - Part 6. GT file technique in abruptly curved canals[J]. Int EndodJ, 2001, 34(3): 250-259.
  • 6Tanomaru-Filho M, Jorge EG. Radiopacity evaluation of new root canal filling materials by digitalization of images [J]. J Endod, 2007, 33(3): 249-251.
  • 7Sonntag D, Ott M, Nook K, et al. Root canal preparation with the NiTi systems K3, Mtwo and ProTaper[J]. Aust EndodJ, 2007, 33(2): 73-81.
  • 8Chaves Cravetro DM, Guiomar de Azevedo BM, Lopes BM. Fatigue resistance of engine-driven rotary nickel-titanium endodonticinstruments[J]. J Endod, 2002, 28(11): 765-769.
  • 9Haikel Y, Serfaty R, Bateman G, et al. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments[J]. J Endod, 1999, 25(6): 434-440.
  • 10Foschi F, Nucci C, Montebugnoli L, et al. SEM evaluation of canal wall dentine following use of Mtwo and ProTaper NiTi rotary instruments[J].Int EndodJ, 2004, 37(12): 832-839.