摘要
针对包钢热电厂6#130 t/h锅炉严重结焦的现状,进行了锅炉的冷态试验,包括燃烧器的检查、风速的测定及调平和炉内冷态空气动力场试验法,找出结焦的原因,提出技改措施,减轻机组结焦程度,使机组能正常运行.
Furnace test was carried out for severe slagging of 6# 130 t/h pulverized coal fired boiler in thermal power plant of Baotou Iron Steel(Group)Co.This test includes the combustor check,the wind velocity measurement and leveling and the cold air dynamic field test in furnace in order to find the cause of the slagging of boiler 6#.The technique reform was put forward to lighten the slagging and assure the normal running of the boiler.
出处
《内蒙古科技大学学报》
CAS
2011年第1期70-72,共3页
Journal of Inner Mongolia University of Science and Technology
基金
内蒙古自然科学基金重大资助项目(20080404ZD07)
内蒙古科技大学创新基金资助项目(2009NC056)