摘要
In this paper, the X-rays emitted from the Rhodotron-TT200 cavity have been studied in depth. We found that the Bremsstrahlung interaction is the only contribution of X-ray generation important to safety. The X-ray dose rate in the Rhodotron vault is calculated for normal conditions based on MCNP4C results. The presented calculation shows good agreement with the experimental measurements, which consequently confirms the reliability of the calculation for use in shielding design and other safety aspects.
In this paper, the X-rays emitted from the Rhodotron-TT200 cavity have been studied in depth. We found that the Bremsstrahlung interaction is the only contribution of X-ray generation important to safety. The X-ray dose rate in the Rhodotron vault is calculated for normal conditions based on MCNP4C results. The presented calculation shows good agreement with the experimental measurements, which consequently confirms the reliability of the calculation for use in shielding design and other safety aspects.