期刊文献+

管式磁微粒化学发光免疫分析法测定玉米样品中的黄曲霉毒素B1 被引量:6

Development of a sensitive magnetic particles chemiluminescence enzyme immunoassay for determination of aflatoxin B1 in corn
原文传递
导出
摘要 开发了一种管式磁微粒化学发光免疫分析法测定玉米样品中黄曲霉毒素B1的方法,该方法使待测玉米样品中的黄曲霉毒素B1、辣根过氧化物酶标记的黄曲霉毒素B1与异硫氰酸荧光素(FITC)标记的黄曲霉毒素B1单克隆抗体在均相体系中发生竞争性免疫反应,再加入用抗FITC抗体包被的磁微粒作分离剂,抗原抗体复合物结合在磁微粒上,在磁场中经分离、洗涤后加发光底物,检测发光强度,测定玉米样品中黄曲霉毒素B1的含量.此方法标准曲线线性范围为0.05~5ng/mL,检测限为0.02ng/mL,批内相对标准偏差小于9%,批间相对标准偏差小于15%,具有良好的稳定性和重现性. A sensitive magnetic particles chemiluminescence enzyme immunoassay for determination of aflatoxin B1(AFB1) in corn was developed and validated.The method was developed based on a competitive immunoreaction format.Immunocomplex was formed through the competitive immunoreaction among AFB1 antigen,horseradish peroxidase-labeled AFB1 antigen and fluorescein isothiocyanate labeled anti-AFB1 monoclonal antibody.Immunocomplex combined with anti-fluorescein isothiocyanate (FITC) antibody coated magnetic particles.The magnetic particles served as both the solid phase and separator.The horseradish peroxidase(HRP)-luminol-hydrogen peroxide chemiluminescent system was chosen as the detection system.This method had a detection limit of 0.02 ng/mL and a linear range of 0.05-5 ng/mL.The intra-assay relative standard deviations were less than 9%.The interassay relative standard deviations were less than 15%.The recoveries were from 94.7% to 109%.The method has been successfully applied to the detection of aflatoxin B1(AFB1) in corn.
出处 《中国科学:化学》 CAS CSCD 北大核心 2011年第7期1177-1183,共7页 SCIENTIA SINICA Chimica
基金 国家高技术研究发展计划(863计划)(SQ2010AA0220249001)资助
关键词 黄曲霉毒素B1 化学发光免疫分析 磁性微粒子 玉米样品 aflatoxin B1 chemiluminescence enzyme immunoassay magnetic particles corn
  • 相关文献

参考文献11

  • 1HajianR,Ensafi AA.Determination of aflatoxins B1and B2 by adsorptive cathodic stripping voltammetry in groundnut. Food Chemistry . 2009
  • 2Quinto M,Spadaccino G,Palermo C,Centonze D.Determination of aflatoxins in cereal flours by solid-phase microextraction coupled with liquid chromatography and post-column photochemical derivatization-fluorescence detection. Journal of Chromatography A . 2009
  • 3Li PW,Zhang Q,Zhang W.Immunoassays for aflatoxins. Trends in Analytical Chemistry . 2009
  • 4Xiulan S,Xiaolian Z,Jian T, et al.Preparation of gold-labeled antibody probe and its use in immunochromatography assay for detection of aflatoxin B1. International Journal of Food Microbiology . 2005
  • 5Saha D,Acharya D,Roy D,et al.Simultaneous enzyme im-munoassay for the screening of aflatoxin B1and ochratoxin A in chili samples. Analytica Chimica Acta . 2007
  • 6Nagwa H S,Laura M,Giuseppe P.Electrochemical immu-nosensor for determination of aflatoxin B1in barley. Ana-lytica Chimica Acta . 2004
  • 7Piermarini S,Micheli L,Ammida NH,Palleschi G,Moscone D.Electrochemical immunosensor array using a 96-well screen-printed microplate for aflatoxin B1 detection. Biosensors and Bioelectronics . 2007
  • 8A Tarin,M G Rosell,X Guardino.Use of high performance liquid chromatography to assess airborne mycotoxins aflatoxins and ochratoxin A. Journal of Chromatography . 2004
  • 9KHAYOON W S,,SAAD B,YAN C B,et al.Determination of aflatox-ins in animal feeds by HPLC with multifunctional column clean-up. Food Chemistry . 2010
  • 10Kussak A,Andersson B,Andersson K.Immunoaffinity Column Clean-up for the High-Performance Liquid Chromatographic Determination of Aflatoxins B1 , B2 , G1 , G2 , M1 and Q1 in Urine. Journal of Chromatography B . 1995

同被引文献125

引证文献6

二级引证文献76

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部