摘要 采用UV-Fenton高级化学氧化法处理酸性含氰废水,探讨了操作条件对氰化物处理效果的影响,结果表明:在pH值为3.5~4.5,停留时间为80 min,FeSO4与H2O2质量比为60∶1时,氰化物去除率达95%以上,出水中氰化物的质量浓度可达到20 mg/L以下,取得较好的处理效果,满足出水水质要求,该方法能够较好地去除酸性含氰废水中的氰化物。 UV-Fenton advanced chemical oxidation process was used to treat acidic cyanide containing wastewater,and the influence of operation condition on the treatment effect was discussed.The results showed that: when the pH value was 3.5-4.5,the retention time was 80 min,the mass ratio of FeSO4 to H2O2 was 60 ∶ 1,the removal rate of cyanide reached 95% or above,and the mass concentration of cyanide in the effluent water was below 20 mg/L.It could be seen that,using the said process to treat acidic cyanide containing wastewater could gain a good effect;the cyanide was removed effectively,and the effluent water quality met the discharge standard.
出处 《工业用水与废水》 CAS 2011年第3期21-23,共3页 Industrial Water & Wastewater
关键词 UV-Fenton法 含氰废水 影响因素 去除率 UV-Fenton process cyanide containing wastewater influencing factors removal rate