期刊文献+

Determination of phthalate esters in physiological saline solution by monolithic silica spin column extraction method 被引量:2

Determination of phthalate esters in physiological saline solution by monolithic silica spin column extraction method
下载PDF
导出
摘要 Monolithic silica spin column extraction (MonoSpin-SPE) was developed as a simple, sensitive, and eco-friendly pretreatment method which combined with ultra-fast liquid chromatography-mass spectrometry (UFLC-MS) to determine the levels of six phthalate esters, dimethyl- (DMP), diethyl- (DEP), dipropyl- [ DPrP], butyl-benzyl- (BBP), dicyclohexyl- (DcHP), and di-n-octyl-(DOP) phthalate in physiological saline samples. Under optimized experimental conditions, the method was linear in the following ranges: 0.2- 50 μg/L for DMP, DEP, DPrP, DcHP and DOP; 5- 100 μg/L for BBP. The correlation coefficients (R2 ) were in the range of 0. 9951 - 0. 9995 for all the analytes and the limits of detection (LODs) and limits of quantification (LOQs) were in the ranges of 0.02 - 0.9 μg/L and 0.08 - 2.7μg/L, respectively. The pretreatment process showed good reproducibility with inter-day and intra-day relative standard deviations (RSDs) below 8.5% and 11.2%, respectively. This method was used to determine the levels of six phthalate esters in physiological saline samples and the recoveries ranged from 71.2% to 107.3%. DMP and DEP were found in actual physical saline samples (brand A and brand B). Monolithic silica spin column extraction (MonoSpin-SPE) was developed as a simple, sensitive, and eco-friendly pretreatment method which combined with ultra-fast liquid chromatography-mass spectrometry (UFLC-MS) to determine the levels of six phthalate esters, dimethyl- (DMP), diethyl- (DEP), dipropyl- [ DPrP], butyl-benzyl- (BBP), dicyclohexyl- (DcHP), and di-n-octyl-(DOP) phthalate in physiological saline samples. Under optimized experimental conditions, the method was linear in the following ranges: 0.2- 50 μg/L for DMP, DEP, DPrP, DcHP and DOP; 5- 100 μg/L for BBP. The correlation coefficients (R2 ) were in the range of 0. 9951 - 0. 9995 for all the analytes and the limits of detection (LODs) and limits of quantification (LOQs) were in the ranges of 0.02 - 0.9 μg/L and 0.08 - 2.7μg/L, respectively. The pretreatment process showed good reproducibility with inter-day and intra-day relative standard deviations (RSDs) below 8.5% and 11.2%, respectively. This method was used to determine the levels of six phthalate esters in physiological saline samples and the recoveries ranged from 71.2% to 107.3%. DMP and DEP were found in actual physical saline samples (brand A and brand B).
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第2期92-99,共8页 药物分析学报(英文版)
基金 supported by the National Natural Science Foundation of China(Nos.90813015,20935002)
关键词 monolithic silica spin column phthalate esters physiological saline samples ultra fast liquid chromatography- mass spectrometry (UFLC-MS) monolithic silica spin column phthalate esters physiological saline samples ultra fast liquid chromatography- mass spectrometry (UFLC-MS)
  • 相关文献

参考文献25

  • 1Castillo M,BarcelD.Analysis ofindustrial effluents to determine endo-crine-disrupting chemicals. Trends in Analytical Chemistry . 1997
  • 2Saillenfait AM,Gallissot F,SabatéJP.Evaluation of the development toxicity of diallyl phthalate administered orally to rats. Food ChemToxi-col . 2008
  • 3Matsumoto M,Koizumi MH,Ema M.Protentional adverse effects of phthalic acid esters on human health:a reviewof recent studies onrepro-duction. Regulatory Toxicology and Pharmacology . 2008
  • 4Sathyanarayana S.Phthalates and children s health. Curr Probi Prediatr Adolesc Health Care . 2008
  • 5US-EPA.Code of Federal Regulation. 40CFRPart136 . 1992
  • 6Férez Feás P,Barciela Alonso MC,Pe a-Vázquez E,et al.Phthalates determinationin physiological salinesolutions by HPLC-ES-MS. Talanta . 2008
  • 7Carlo MD,Pepe A,Sacchetti Get al.Determination of phthalate esters in wine using solid-phase extraction and gas chromatography-mass spec-trometry. Food Chemistry . 2008
  • 8Jiménez FJL,Rubio S,Bendito DP.Determination of phthalate esters in sewage by hemimicelles-based solid-phase extraction and liquid chroma-tography-mass spectrometry. Analytica Chimica Acta . 2005
  • 9Kato M,Sakai-Kato K,Toyo oka Tet al.Effect of preparatory condi-tions onthe performance of photopolymetizedsol-gel monoliths for capil-lary electrochromatography. Journal of Chromatography A . 2002
  • 10Shintani Y,Zhou X,Furuno Met al.Monolithic silica column for in-tube solid-phase microextractioncoupledto high performanceliquid chro-matography. Journal of Chromatography A . 2003

同被引文献23

引证文献2

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部