期刊文献+

The clinical value of enzyme-multiplied immunoassay technique monitoring the plasma concentrations of cyclosporine A after renal transplantation 被引量:2

The clinical value of enzyme-multiplied immunoassay technique monitoring the plasma concentrations of cyclosporine A after renal transplantation
下载PDF
导出
摘要 The feasibility and the clinical value of the enzyme-multiplied immunoassay technique (EMIT) monitoring of blood concentrations of cyclosporine A (CsA) in patients treated with CsA were investigated after kidney transplantation. The validation method was performed to the EMIT determination of CsA blood concentration, the CsA whole blood trough concentrations (Co) of patients in different time periods after renal transplantation were monitored, and combined with the clinical complications, the statistical results were analyzed and compared. EMIT was precise, accurate and stable, also with a high quality control. The mean postoperative blood concentration of CsA was as follows: 〈1 month, (281.4± 57.9)ng/mL; 2 - 3 months, (264.5 ± 41.2) ng/mL; 4 - 5 months, (236.4 ± 38.9) ng/mL; 6 - 12 months, (206.5± 32.6)ng/mL; 〉12 months, (185.6± 28.1)ng/mL. The toxic reaction rate of CsA blood concentration within the recommended therapeutic concentration was 14.1%, significantly lower than that of the none-recommended dose group (37.2%) (P〈0.05); the transplantation rejection rate was 4.4%, significantly lower than that of the none- recommended dose group (22.5%) (P〈0.05). Using EMIT to monitor the blood concentration of CsA as the routine laboratory method is feasible, and is able to reduce the CsA toxicity and rejection significantly, leading to achieving the desired therapeutic effect. The feasibility and the clinical value of the enzyme-multiplied immunoassay technique (EMIT) monitoring of blood concentrations of cyclosporine A (CsA) in patients treated with CsA were investigated after kidney transplantation. The validation method was performed to the EMIT determination of CsA blood concentration, the CsA whole blood trough concentrations (Co) of patients in different time periods after renal transplantation were monitored, and combined with the clinical complications, the statistical results were analyzed and compared. EMIT was precise, accurate and stable, also with a high quality control. The mean postoperative blood concentration of CsA was as follows: 〈1 month, (281.4± 57.9)ng/mL; 2 - 3 months, (264.5 ± 41.2) ng/mL; 4 - 5 months, (236.4 ± 38.9) ng/mL; 6 - 12 months, (206.5± 32.6)ng/mL; 〉12 months, (185.6± 28.1)ng/mL. The toxic reaction rate of CsA blood concentration within the recommended therapeutic concentration was 14.1%, significantly lower than that of the none-recommended dose group (37.2%) (P〈0.05); the transplantation rejection rate was 4.4%, significantly lower than that of the none- recommended dose group (22.5%) (P〈0.05). Using EMIT to monitor the blood concentration of CsA as the routine laboratory method is feasible, and is able to reduce the CsA toxicity and rejection significantly, leading to achieving the desired therapeutic effect.
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第2期139-142,共4页 药物分析学报(英文版)
基金 supported by the Project 973 Monitoring of the Immune Status and Rejection After Organ Transplantation"(2009CB522400) the National Natural Science Foundation of China(No.30972947)
关键词 enzyme-multiplied immunoassay technique renal transplantation cyclosporin A blood concentration monitoring enzyme-multiplied immunoassay technique renal transplantation cyclosporin A blood concentration monitoring
  • 相关文献

参考文献3

二级参考文献31

共引文献34

同被引文献15

引证文献2

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部