期刊文献+

不同心率水平256层CT前瞻性心电门控冠状动脉成像质量评价 被引量:3

Image quality assess for patients with different heart rate by 256-silce computed tomography coronary angiography with prospective ECG-gating
下载PDF
导出
摘要 目的:比较不同心率水平256层CT前瞻性心电门控冠状动脉成像的图像质量。方法:对临床拟诊冠心病的200例患者行256层CT前瞻性心电门控冠状动脉成像,根据心率分为两组:第1组,50次/min≤心率<70次/min(n=99);第2组,70次/min≤心率<90次/min(n=111)。用双盲法评价两组的图像质量。结果:第1组患者可评估的冠状动脉节段为1 410个(94.95%),其中1 123个(79.65%)节段图像质量优秀,253个(17.94%)节段图像质量为良,34个(2.41%)节段图像质量为差;第2组可评估的冠状动脉节段为1 571个(94.35%),其中1 208个(76.89%)节段图像质量优秀,309个(19.67%)节段图像质量为良,54个(3.44%)节段图像质量为差,两组之间差异均无统计学意义(P>0.05)。结论:心率在90次/min以下的患者能进行256层CT前瞻性心电门控冠状动脉成像,图像质量能满足诊断要求。 Objective:To compare image quality of patients with different heart rate(HR)by 256-silce computed tomography coro-nary angiography(CTCA)using prospective electrocardiogram(ECG)-gating.Methods:Two hundred patients with suspected coronary artery disease underwent 256-slice CTCA using prospective ECG-gating.Patients were divided into two groups according to their HR:the first group(50 b.p.m≤HR 〈 70 b.p.m,n = 99)and the second group(70 b.p.m≤HR 〈 90 b.p.m,n = 111).Image quality was e-valuated between those two groups.Results:Total 1410(94.95%)segments of the first group were evaluated,among which 1 123(79.65%)segments were classified as excellent,253(17.94%)were good and 34(2.48%)were bad.Total 1 571(94.35%)segments of the second group could be evaluated,1 208(76.89%)segments were classified as excellent,309(19.67%)were good and 54(3.44%)were bad.Conclusion:The patients with HR 〈 90 b.p.m can undergo CTCA using prospective ECG-gating.Image quality can satisfy the diagnostic requirement.
出处 《南京医科大学学报(自然科学版)》 CAS CSCD 北大核心 2011年第6期856-859,共4页 Journal of Nanjing Medical University(Natural Sciences)
关键词 体层摄影术 X线计算机 前门控技术 冠状动脉血管成像 tomography X-ray computed prospective ECG gating coronary angiography
  • 相关文献

参考文献4

二级参考文献16

  • 1张森,杜湘珂,李剑颖.心电图调制电流对于容积CT心脏扫描图像质量及曝光剂量影响的评估[J].中华放射学杂志,2006,40(9):974-976. 被引量:45
  • 2Hunold P, Vogt FM, Schmermund A, et al. Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology,2003,226 : 145-152.
  • 3Trabold T, Buchgeister M, Kuttner A, et al. Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Rofo, 2003, 175: 1051-1055.
  • 4Leber AW, Knez A, Becker A, et al. Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Call Cardiol, 2004, 43 : 1241-1247.
  • 5Leber AW, Becker A, Knez A, et al. Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary, system : a comparative study using intravascular ultrasound. J Am Coil Cardiol, 2006, 47:672-677.
  • 6Mnllet NR, Cademartiri F, van Mieghem CA, et al. High- resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography.Circulation, 2005, 112:2318-2323.
  • 7Raft GL, Gallagher MJ, O'Neill WW, et al. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol, 2005, 46:552-557.
  • 8Hsieh J, Londt J, Vass M, et al. Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography. Med Phys, 2006, 33:4236-4248.
  • 9Nieman K, Cademartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation, 2002, 106: 2051-2054.
  • 10Flohr TG, Schoepf UJ, Kuettner A, et al. Advances in cardiac imaging with 16-section CT systems. Acad Radiol, 2003, 10: 386-401.

共引文献243

同被引文献33

  • 1Matt D,Scheffel H,Leschka S. Dual-source CT coronary angiography:image quality,mean heart rate,and heart rate variability[J].AJR,2007,(3):567-573.
  • 2Brodoefel H,Reimann A,Heuschmid M. Non-invasive coronary angiography with 16-slice spiral computed tomography:image quality in patients with high heart rates[J].{H}European Radiology,2006,(7):1434-1441.
  • 3Beister M,Kolditz D,Kalender W A. Iterative reconstruction methods in X-ray CT[J].Phys Med,2012,(2):94-108.
  • 4Mieville F A,Gudinchet F,Brunelle F. Iterative reconstruction methods in two different MDCT scanners:physical metrics and 4-alternative forced-choice detectability experiments-a phantom approach[J].Phys Med,2013,(1):99-110.
  • 5Ghetti C,Ortenzia O,Serreli G. CT iterative reconstruction in image space:a phantom study[J].Phys Med,2011,(2):161-165.
  • 6Funama Y,Taguchi K,Utsunomiya D. Combination of a low tube voltage technique with the hybrid iterative reconstruction (iDose)algorithm at coronary CT angiograph[J].{H}Journal of Computer Assisted Tomography,2011,(4):480-485.
  • 7Stolzmann P,Goetti R,Baumueller S. Prospective and retrospective ECG-gating for CT coronary angiography perform similarly accurate at low heart rates[J].{H}EUROPEAN JOURNAL OF RADIOLOGY,2011,(1):85-91.
  • 8Hosch W,Stiller W,Mueller D. Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction[J].{H}EUROPEAN JOURNAL OF RADIOLOGY,2012,(11):3568-3576.
  • 9Herzog BA, Husmann L, Burkhard N, et al. Accuracy of low-dosecomputed tomography coronary angiography using prospective elec-trocardiogram-triggering: first clinical experience [ J]. Eur Heart J,2008,29(24) :3037 -3042.
  • 10Klass 0, Walker M, Siebach A, et al. Prospectively gated axial CTcoronary angiography : comparison of image quality and effective radi-ation dosebetween 64-and 256-slice CT [ J]. Eur Radiol, 2010, 20(5):1124-1131.