摘要
为了改善传统恒温恒湿空调系统能源浪费的现状,介绍分离式热管辅助除湿系统的工作原理,分析该系统的评价指标以及效率影响因素,并提出后续工作建议。
In order to improve the status of energy waste by traditional energy-saving air-conditioning system,introduces the working theory of the separate heat pipe assisted dehumidification system,analyzes the evaluation and efficiency factors of the system,and proposes some follow-up recommendations.
出处
《制冷与空调》
2011年第3期15-19,97,共6页
Refrigeration and Air-Conditioning
关键词
分离式热管
潜热负荷
除湿
恒温恒湿
空调
separate heat pipe
latent heat load
dehumidification
constant temperature and humidity
air-conditioning